With the Gemini control panels GEM-P816, GEM-P1632, GEM-P1664, can I use the keypad to enable the Test Timer feature using "Direct Address Programming"?
Yes, Test Timer programming can be performed using the keypad only when the following are both true:
- The control panel firmware version is 30 or greater
--and--
- An alphanumeric keypad (the GEM-RP1CAe2 is used in the example below)
To program Test Timer using Direct Address (keypad) programming:
- Enter the Dealer Keypad Program Code and press FUNCTION. The keypad will display the zone directory.
- Press BYPASS until "Activate Program" is displayed and press YES (press STAY or INSTANT). The keypad will display "# Area 1 Keypads, Enter # KPs".
- Press NO (AWAY or INSTANT) until "Test Timer" is displayed.
- Program Test Timer day(s) of week and time, and press ON/OFF to save.
- Press RESET once. Keypad will display "0000".
- Press 0840 and press 1.
- Press ON/OFF to save.
- Press RESET to exit Direct Address programming.