Answer:
Your DL-Windows software version is outdated. If you have discovered a lock without a model number listed (see example image, below), it is likely that your DL-Windows software is older than the model itself.
...
View Answer
Answer:
With the release of DL-Windows V5.5.3, we have added a Two-Door Settings tab in the Features screen that includes the ability to activate Passage Mode in either the main relay or the auxiliary relay, or both relays together. Note: This new Two-Door...
View Answer
Answer:
The ArchiTech series N90 (cylindrical) N95 (mortise) support the iLock Bluetooth app. The model number must contain the letter J (N90J or N95J) or T (N90T or N95T) to indicate that the Bluetooth option is present.
...
View Answer
Answer:
No, an RR-RECEIVER is not necessary to pair the RR-1BUTTON to a NETWORXPANEL because the NETWORXPANEL already has a receiver built into it. To pair the RR-1BUTTON to a NETWORXPANEL, a NETDK or NETPDK locking device must be wired to the system,...
View Answer
Answer:
When programming the RR-1BUTTON to be used with a NETWORXPANEL, the main ("primary") relay always activates first, usually bypassing the auxiliary relay unless otherwise programmed to do so.
...
View Answer
Answer:
After the lock has been physically defaulted, proceed as follows:
...
View Answer
Answer:
As the NETHIDNSPANEL does not include a keypad, it is not possible to perform keypad Function 65 (normally used to pair the RR-1BUTTON to a Networx lockset or NETWORXPANEL). However, you can purchase the RR-TRILOGYKIT which includes a small...
View Answer
Answer:
Whether the NETWORXPANEL is wired with one or two keypads or is configured for a single door or for "Two Door Mode", the pairing of a wireless remote release button to the NETWORXPANEL is the same. If the NETWORXPANEL is wired with two keypads,...
View Answer
Answer:
When in "Two Door Mode", the shunting of the Remote Release Input terminals 26 and 27 (or the activation of a paired wireless remote release button) will always activate BOTH relays, unlocking both doors at the same time.
View Answer
Answer:
Up to 10 wireless remote release buttons can be paired to the NETWORXPANEL.
...
View Answer
Answer:
The pictures shown below represent two views of an actual AL-IMEPOEP, with color coded lines and numbers indicating the various dimensions (in inches).
View Answer
Answer:
As with most upgrades, the potential for data loss always exists. We therefore strongly recommend that prior to upgrading your Lenel OnGuard software, you always back up the following configuration file:
...
View Answer
Answer:
The dimensions are (WxHxD) 7 x 3½ x 1½" (17.8 x 8.9 x 3.8cm)
View Answer
Answer:
Other than checking the batteries for adequate voltage, remove the lock from the door and inspect the ribbon cable for damage. A damaged ribbon often causes a short on the battery connections, drastically decreasing battery life.
View Answer
Answer:
The versatility of the Alarm Lock Networx system allows the Gateways and wireless locks to communicate over many different types of networks. For this reason, it is always a good idea to “bench test” the equipment in a controlled...
View Answer
Answer:
Leave this selection blank, as the Gateway will automatically select an available channel.
View Answer
Answer:
Two Door Mode Can Limit User Access:
...
View Answer
Answer:
DL-Windows software allows you to connect your PC with your lock. Although DL-Windows cannot make your lock a wireless lock; however, the following locksets have wireless capability:
...
View Answer
Answer:
There is no specified length of the RJ-45 cable between two devices. However, we recommend you consider the following variables:
...
View Answer
Answer:
To move Existing Networx Account Files to a New Computer, follow the steps below:A. COPY Your EXISTING ACCOUNT FILES
...