FAQs
When using an RR-1BUTTON Wireless Remote Release Button on a 2-relay device, which relay activates first?
When programming the RR-1BUTTON to be used with a NETWORXPANEL, the main ("primary") relay always activates first, usually bypassing the auxiliary relay unless otherwise programmed to do so.
If "Two-Door Mode" is programmed, where up to two doors can be controlled using two keypads (with one keypad, designated as "primary", controlling door #1 and another keypad, designated as "secondary" controlling door #2). With "Two Door Mode" programmed, the main and auxiliary relays activate at the same time.
Activate "Two Door Mode" in the DL-Windows Features screen > Relay tab. See the NETWORXPANEL installation instructions (WI1856) for complete "Two Door Mode" wiring and setup information.