Answer:
Before using the Honeywell Compass downloader software you MUST "suspend" the StarLink Connect software. Double-click the StarLink Connect icon in the System Tray, then click the Exit tab and...
View Answer
Answer:
The StarLink Connect software application will only store one radio ID number for each software type (one for Honeywell, one for DSC), however the software will store the other user-defined fields associated with the radio ID...
View Answer
Answer:
No. When the panel manufacturer is selected and downloaded into the radio from the NOC website (www.NapcoNOC.com), the iBridge app automatically displays the correct manufacturer's keypad type.
...
View Answer
Answer:
1. After registering the radio on www.NapcoComNet.com, you must log into the Radio Management Center at www.NapcoNOC.com, click the StarLink Connect tab, then click Panel Configuration.
...
View Answer
Answer:
----------------------------------------------------------------
Please see the following video:
View Answer
Answer:
If Opening / Closing Signals are programmed, a signal is transmitted to the central station whenever the control panel is either armed or disarmed.
...
View Answer
Answer:
The 4/2 reporting codes (examples shown below) will always report in accordance with the 2 characters programmed. All restores will have an "E" in the second digit (this "E" is hardcoded within the radio firmware and in the NOC and so therefore...
View Answer
Answer:
No, an RR-RECEIVER is not necessary to pair the RR-1BUTTON to a NETWORXPANEL because the NETWORXPANEL already has a receiver built into it. To pair the RR-1BUTTON to a NETWORXPANEL, a NETDK or NETPDK locking device must be wired to the system,...
View Answer
Answer:
When programming the RR-1BUTTON to be used with a NETWORXPANEL, the main ("primary") relay always activates first, usually bypassing the auxiliary relay unless otherwise programmed to do so.
...
View Answer
Answer:
At an Administrator command prompt, type the following command:
net user administrator /active:yes
Note: This information can be found by performing a Google Search.
View Answer
Answer:
Please refer to the version specific CA4K System Requirements document and also the CA4K Help file. Go to www.napcoaccesspro.com, Select Resources, then select Technical Library, Press Browse by Product Type and Select CA4K Software to locate...
View Answer
Answer:
YES...All the EPI information in the CardAccess 3000 database will migrate over to the CA4K database while executing the CA4K Migration utility. Even though all templates are stored in the database, it is highly recommended to manually copy over all...
View Answer
Answer:
If all the Network settings are correct and the CA4K is programmed correctly, verify the following things:
...
View Answer
Answer:
No. StarLink dual path reporting communicates from the radio installation site to the NAPCO NOC (www.NapcoNOC.com) over an IP and / or a radio path. Once the signal reaches the NOC server it is processed normally over dial up (telephone...
View Answer
Answer:
No. When reporting over the IP path, the control panel can report in either Contact ID or 4/2 format.
View Answer
Answer:
The StarLink dual path and StarLink Connect radios are capable of dual path reporting from the radio installation site to the NAPCO NOC (www.NapcoNOC.com) over the Internet with cellar (telephone) backup.
...
View Answer
Answer:
The NL-MODCONFIG software cannot alter the IP address of the RJ-45 port located on the right side of the IBR-ZREMOTE.
...
View Answer
Answer:
Before using the Honeywell Compass downloader software you MUST "suspend" the StarLink Connect software. Double-click the StarLink Connect icon in the System Tray, then click the Exit tab and click Suspend (see image below).
...
View Answer
Answer:
----------------------------------------------------------------
Please see the following video:
View Answer
Answer:
The Test Timer schedule is programmed into the control panel using NAPCO's PCD-Windows Quickloader software. If Test Timer is programmed, an automatic test report is transmitted to the central station on the scheduled day(s) at the scheduled...
View Answer
Answer:
The correct system time and time zone settings must be set using the iBridge mobile app:
...
View Answer
Answer:
The StarLink Connect software application will only store one radio ID number for each software type (one for Honeywell, one for DSC), however the software will store the other user-defined fields associated with the radio ID number.
...
View Answer
Answer:
No. When the panel manufacturer is selected and downloaded into the radio from the NOC website (www.NapcoNOC.com), the iBridge app automatically displays the correct manufacturer's keypad type.
...
View Answer
Answer:
1. After registering the radio on www.NapcoComNet.com, you must log into the Radio Management Center at www.NapcoNOC.com, click the StarLink Connect tab, then click Panel Configuration.
...
View Answer
Answer:
No, the radio must be powered with 12 volts from the GEMC control panel to allow uploading and downloading.
View Answer
Answer:
The SLE-CDMA-FIRE, supplied in a red plastic enclosure, is UL 864 9th Edition approved and supports NFPA 2007, 2010 and 2013 service plans. UL requires the SLE-CDMA-FIRE to be mounted on a single-, double- or...
View Answer
Answer:
The following summarizes the minimum required NOC programming (www.NapcoNOC.com) and system wiring when connecting a StarLink Fire Radio to the DACT of an FACP, utilizing dial capture mode reporting. Check the installation and programming...
View Answer
Answer:
Yes. UL requires that the 9SLE10KHARN harness be installed within the FACP enclosure, allowing the resistor network within the 9SLE10KHARN wiring harness to provide EOLR functionality at the radio input. This...
View Answer
Answer:
The answer depends on the version of NFPA 72 to which the local, state or federal building code conforms, and the version enforced by the AHJ. The two versions for NFPA 72 that allow for a sole path communicator are version 2010 and version...
View Answer
Answer:
Yes, click here to access a printable wiring diagram and a summary of NOC programming steps. Also, the SLE radio rear enclosure includes mounting holes to specifically accommodate single-, double- and triple-gang electrical...
View Answer
Answer:
When Input 2 and/or Input 3 are programmed for Supervision, you must install the 9SLE10KHARN harness and wire accordingly (this harness is installed with two 10k resistors, one in series, the other in parallel; see image at...
View Answer
Answer:
The opening of the FACP trouble relay will NOT cause PGM1 to send a trouble indication to the central station.
...
View Answer
Answer:
Input 2 and Input 3 on the Commercial series StarLink SLE radios are supervised; therefore the two supplied 10K EOLR must be installed. If either Input is open, the radio will send a trouble signal to the central station every 24 hours until...
View Answer
40 Results Per Page | Showing
881-920 of 1896 Results
|
1
|
2
|
3
|
4
|
5
|
6
|
7
|
8
|
9
|
10
|
11
|
12
|
13
|
14
|
15
|
16
|
17
|
18
|
19
|
20
|
21
|
22
| 23 |
24
|
25
|
26
|
27
|
28
|
29
|
30
|
31
|
32
|
33
|
34
|
35
|
36
|
37
|
38
|
39
|
40
|
41
|
42
|
43
|
44
|
45
|
46
|
47
|
48