FAQs
Do you have a list of the basic iBridge configuration requirements?
1. Registration at www.NapcoComNet.com
A. Remote Panel Programming – N/A
B. Central Station Reporting – N/A
C. Virtual Keypad Control – Required
D. Local Keypad Control – N/A
2. Remote Panel Programming Mode
A. NL-MODCONFIG – Factory settings should be OK unless a static IP address is desired
B. Two RJ-45 Network Connections
a. Router must have Port 10081 Opened
b. TCP/IP must be enabled in Alarm Panel
C. RJ-12 Download Connection
3. Central Station Reporting Mode
A. NL-MODCONFIG – Must set central station IP address, other settings should be OK unless a static IP address is desired
B. Two RJ-45 Network Connections
- Router Port 5001 must be opened (unblocked)
C. RJ-12 Download Connection
4. Virtual Keypad Control Mode
A. NL-MODCONFIG – Factory settings should be OK unless a static IP address is desired
- PC Preset / RCM port IP addresses may need to be verified and/or reset.
B. Keypad Address and Type – Set to meet current keypad configurations
C. Two RJ-45 Network Connections
- Router ports 5002 and 5011 must be opened (unblocked)
D. RJ-12 Download Connection – Not Required
5. Local Keypad Control Mode – Used if user wants IBR-ITAB operation but not remote access
A. NL-MODCONFIG – Factory settings should be OK unless a static IP address is desired
B. Keypad Address and Type – Set to meet current keypad configurations
C. Two RJ-45 Network Connections
D. RJ-12 Download Connection – Not Required
- Any combination of modes can be used provided requirements of each are met