What is the Mapping for the Inputs on an Accelaterm (CICP2800) 8/16 door controller?
Note: An 8 door Accelaterm can have up to 3 I/O expansion boards connected to it. A 16 door Accelaterm can only have 2 I/O expansion boards connected to it. Each I/O expansion board contains 16 additional inputs and 16 additional relays.
http://tech.napcosecurity.com/index.php/techlibrary/downloadfile/id/1804/embed/iframe
8 Door Accelaterm Input Mapping (Maps identical to an 8 door Superterm and Turbo Superterm):
Inputs 1- 16 (There are 8 readers with 2 inputs on each reader (8X2=16). These inputs are identical to the 8 door Superterm and Turbo Superterm mapping. By default, they are used for Door Sensors and Request To Exits)
Inputs 17 -24 (These are 8 auxiliary inputs which come standard on the 8 and 16 door Accelaterm).
Can have up to 3 Expansion Boards Added:
Inputs 25-40 //Expansion board # 1
Inputs 41-56 //Expansion board # 2
Inputs 57-72 //Expansion board # 3
16 Door Accelaterm Input Mapping :
Inputs 1- 32 (There are 16 readers with 2 inputs on each reader (16X2=32).
Inputs 33-40 (These are 8 auxiliary inputs which come standard on the 8 and 16 door Accelaterm).
Can have up to 2 Expansion Boards Added:
Inputs 41-56 //Expansion board # 1
Inputs 57-72 //Expansion board # 2