FAQs
How do I program a panic button that is hardwired to the GEM-ACM1D?
Program a 24-hour panic button hardwired to the GEM-ACM1D as follows:
- Wire the panic button to the door zone of the GEM-ACM1D with a 2.2k resistor.
- Choose the zone and strap out the zone on the control panel or EZM with a 2.2k resistor.
- In PCD-Windows Quickloader, program the zone as a 24-Hour Zone with no Swinger Shutdown.
- In the System Assignment screen, System Options tab, be sure Enable ACM Access is checked.
- In the Keypad Assignment screen, ACM Assignment tab, for the Door Ajar Zone, type the Zone Number you will be using.