What Point ID codes are sent to central station by the GEM-P9600, GEM-P3200 and GEM-X255 control panels?
The following is a description of Point ID Central Station Report Codes:
Note: Applies to GEM-P816, GEM-P1632 and GEM-P1664 control panel firmware versions 10 and higher; and GEM-P3200, GEM-P9600 and GEM-X255 control panel firmware versions 11 and higher:
Code Event
100 - - - - - - - - - - Auxiliary
110 - - - - - - - - - - Fire Alarm
121 - - - - - - - - - - Ambush
122 - - - - - - - - - - Hold-Up
123 - - - - - - - - - - Panic
130 - - - - - - - - - - Burglary
137 - - - - - - - - - - Keypad Tamper
140 - - - - - - - - - - Keypad Auxiliary
145 - - - - - - - - - - EZM Tamper
150 - - - - - - - - - - 24hr Aux.
151 - - - - - - - - - - Gas Alarm
158 - - - - - - - - - - Heat Alarm
300 - - - - - - - - - - Bus Failure
301 - - - - - - - - - - AC Failure
302 - - - - - - - - - - System Low Battery
303 - - - - - - - - - - Memory Failure
306 - - - - - - - - - - Program Change
321 - - - - - - - - - - Bell Supervision
333 - - - - - - - - - - RF Receiver Failure
351 - - - - - - - - - - Telco Fail Restore
353 - - - - - - - - - - Telemetry (AES) Trouble
354 - - - - - - - - - - Telemetry (AES) Failure
370 - - - - - - - - - - Day Zone Trouble
373 - - - - - - - - - - Fire Trouble
374 - - - - - - - - - - Exit Error (SIA CP-01)
380 - - - - - - - - - - Sensor Watch
381 - - - - - - - - - - Wireless Low Battery or Supervisory
383 - - - - - - - - - - Wireless Tamper
400 - - - - - - - - - - Conditional Close/Open After Alarm/Force Close
401 - - - - - - - - - - Open/Close – By User, Auto, Remote, Easy, or Keyswitch
404 - - - - - - - - - - Fail to Open/Fail to Close
459 - - - - - - - - - - Recent Close (SIA CP-01)
570 - - - - - - - - - - Select Bypass in Conditional Close/Status Report
601 - - - - - - - - - - Communications Test, Manual/DDialer
602 - - - - - - - - - - Communications Test, Periodic/Service Message
607 - - - - - - - - - - Guard Tour Fail/Fault Find Test Start/End
999 - - - - - - - - - - Keyfob Low Battery
The following are Point I.D. reports and are listed as they would appear on an ADEMCO 685 receiver:
Event: XXXX E130 00 C000
XXXX E130 00 C000
Subscriber Event Area # Contact #
ID # Code or User
Alarms
Burglary
XXXX E130 01 C001 Burglary, Zone 1, Area 1
XXXX R130 01 C0001 Restore, Zone 1, Area 1
Burglary/24 Hour Zone
XXXX E123 01 C004 Burglary/24 Hour Zone, Area 1, Zone 4
XXXX R123 01 C004 Restore, Burg/24Hour Zone, Area 1, Zone 4
Ambush
XXXX E121 01 C000 Ambush, Area 1
Keypad Panic
XXXX E123 01 C000 Keypad Panic, Area 1
Keypad Auxiliary
XXXX E140 01 C000 Keypad Auxiliary, Area 1
Keypad Fire
XXXX E110 01 C000 Fire, Area 1
Fire
XXXX E110 01 C008 Fire, Area 1, Zone 8
Opening/Closing
Closing by User
XXXX R401 01 U001 Closing, Area 1, User 1
Opening by User
XXXX E401 01 U014 Opening, Area 1, User 14
Auto Arm (Always User 97)
XXXX R401 01 U097 Auto Arm, Area 1, User 97
Remote Arm/Disarm (Always User 98)
XXXX R401 01 U098 Closing, Area 1, Remote/Local PC
XXXX E401 01 U098 Opening, Area 1, Remote/local PC
Easy Arm (Always User 99)
XXXX R401 01 U099 Closing, Area 1, Easy Arm
Keyswitch Arm/Disarm (Always User 00)
XXXX R401 01 U000 Closing, Area 1, Keyswitch
XXXX E401 01 U000 Opening, Area 1, Keyswitch
Conditional Closing
XXXX R400 01 U001 Closing, Zone Bypassed, Area 1,User 1
Status Report
XXXX R400 01 U001 Closing, Zone Bypassed, Area 1, User 1
XXXX E570 01 C005 Zone Bypass, Area 1, Zone 5
The Conditional closing is sent, followed by the status report, event 570. This sequence of reports is sent when a zone is Auto bypassed.
Select Bypass in Conditional Close
XXXX R400 01 U001 Conditional Close, Area 1, User 1
XXXX E570 01 U001 Manual Bypass, Area 1, Zone 1
Open After Alarm
XXXX E400 01 U003 Open After Alarm, Area 1, User 3
Fail to Open
XXXX E404 01 C000 Fail to Open, Area 1
If an area has not been disarmed, at the end of the Report Suppression window for openings, a Fail to Open report will be generated.
Fail to Close
XXXX R404 02 C000 Fail to Close, Area 2
If an area has not been armed, at the end of the Report suppression window for closings, a Fail to close report will be generated.
Force Close
XXXX R400 01 U097 Auto Arm , Area 1, User 97
In the event of a Fail to Close, if Enable Auto Arm if not closed at end of window is enabled, the panel will arm automatically in 15 minutes. If zones are faulted at the time of auto arm, the panel will auto bypass all faulted zones (including priority zones). This will generate a Force Close report.
System Troubles
AC Failure
XXXX E301 00 C000 AC Failure
XXXX R301 00 C000 AC Failure Restore
Low Battery
XXXX E302 00 C000 Low Battery
XXXX R302 00 C000 Low Battery Restore
Memory Failure
XXXX E303 00 C000 Memory Failure
Sensor Watch
XXXX E380 00 C000 Sensor Watch Trouble
XXXX R380 00 C000 Sensor Watch Trouble Restore
EZM Tamper
XXXX E145 00 C001 EZM 1 Tamper
Telco Fail Restore
XXXX E351 00 C000 Telephone Line Fault
XXXX R351 00 C000 Telephone Line Restore
Bus Failure
XXXX E300 00 C002 Bus Failure
Fire Trouble
XXXX E373 01 C008 Fire Trouble, Area 1, Zone 8
XXXX R373 01 C008 Fire Trouble Restore, Area 1, Zone 8
Keypad Tamper
XXXX E137 00 C000 Keypad Tamper
Day Zone Trouble
XXXX E370 01 C003 Trouble, Area 1, Zone3
XXXX R370 01 C003 Trouble Restore, Area 1, Zone 3
Wireless
RF Receiver Trouble
XXXX E333 00 C000 Receiver Failure/Tamper
Wireless Supervisory
XXXX E381 00 C000 Wireless Supervisory
Wireless Tamper
XXXX E383 00 C000 Transmitter Tamper
Wireless Low Battery (Transmitter)
XXXX E381 00 C000 Wireless Low Battery
Keyfob Low Battery
XXXX E999 00 C000 Keyfob Low Battery
Miscellaneous
Communications Test
XXXX E601 00 C000 Manual Test/Digital Dialer Test
Test Timer
XXXX E602 00 C000 Periodic Test
Service Message
XXXX E602 00 C001 Service Message
Program Change
XXXX E306 00 C000 Program Change
Guard Tour Fail
XXXX E607 00 C000 Guard Tour Fail
Note: If a restore is not displayed for an event, the panel does not send a restore for that event.
Note: The above applies to panel versions 11D – 30 AND versions 1B – 4 of the X-255.