How do I program GEM-WP Panic Transmitter into a GEM-P1632 control panel?
Using the GEM-RP2ASe2 keypad to program the GEM-WP as a panic device for the GEM-P1632 control panel, proceed as follows:
(Note: This same process can also be followed for the GEM-P1664, GEM-P816, GEM-P3200, GEM-P9600, GEM-X255 and the Gemini C-Series (GEMC) control panels).
Enter the Dealer Security Code (default = 4 5 6 7 8 9 for a new control panel) or enter your custom Dealer Program Code if programmed. Press NO ([INSTANT]) repeatedly until "TURNON/PROg" is displayed (if you pass "TURNON/PROg", you can scroll back by pressing the [BYPASS] button). Press YES ([INTERIOR]) to enter the Dealer Program Mode.
Press the NEXT ([INTERIOR]) until the keypad screen reads "KFOB":
For each GEM-WP Transmitter, enter:
- The GEM-WP Transmitter number (01–08). Press [0] [8] for 01-08. Press [FUNCTION]
- The area number to which transmitter is assigned. Press [1] and [2] for Area 1 and 2, respectively. Press [FUNCTION]
- The 6-digit RF ID # printed on the transmitter (enter all numbers and/or letters, including leading "0"s, if any): "0" through "9" = [0] through [9]; "A" = [*] [0]; "B" = [*] [1]; "C" = [*] [2]; "D" = [*] [3]; "E" = [*] [4] and "F" = [*] [5].
- 1-digit checksum number printed on the transmitter. Press [FUNCTION]
- Aux 1 Option (for a panic report, program a 9, for a keypad auxiliary report program an A ([*] [0]).
Press the [ON/OFF] button to save. Note: If programming the GEM-WP to send a panic report, also enable keypad panic to report on alarm. If programming the GEM-WP to send an auxiliary report, also enable keypad auxiliary to report on alarm.
Programming the GEM-WP Transmitters as Zone Input Devices
The button of the GEM-WP may be assigned to a zone. Up to 32 GEM-WPs can be assigned, each reporting to a Central Station, or a pager, and/or annunciating on a keypad with the GEM-WP zone number with a description/location. To assign a GEM-WP to a zone: Program the GEM-WP as you would a transmitter, entering the GEM-WPs ID code, check sum and point number 3 at the appropriate zone.