FAQs
How do I activate the relay inside the Alarm Lock model DL2700?
The DL2700 can be programmed to activate its integral relay upon any numeric keypress (program Function 201), or when the unit is unlocked (program Function 202), as follows:
To activate the relay on any first button press (0-9), use Function 201:
- Enter the Master Code followed by [AL] 2 0 1 [*]
To activate the relay after a valid code, use Function 202:
- Enter the Master Code followed by [AL] 2 0 2 [*]
For the above functions, the relay remains activated for the duration of the "Pass Time" (the time the lock stays unlocked after a valid code entry, programmable between 2-20 seconds; see the programming instructions for details).
To disable the above programmed relay functions, use Function 200:
- Enter the Master Code followed by [AL] 2 0 0 [*]
Electrical specifications:
Relay allows up to 300mA @ 60VDC maximum.
- Blue wire = Common
- Yellow wire = N/O
- Green wire = N/C