Answer:
In addition to the instructions provided, the following may be helpful:
...
View Answer
Answer:
Factory default Alarm Lock devices such as Networx locks, readers, the NETWORXPANEL, etc., that have been discovered and connected to an Air Access system cannot be reverted to their original factory firmware. The Air Access discovery and...
View Answer
Answer:
Your DL-Windows software version is outdated. If you have discovered a lock without a model number listed (see example image, below), it is likely that your DL-Windows software is older than the model itself.
...
View Answer
Answer:
Andy Phelps, Alarm Lock's National Training manager, shows you how to program a Networx lock in the DL-Windows Trilogy lock programming software.
View Answer
Answer:
When restoring your DL-Windows database using any type of backup .bak file, this .bak file must reside in a certain folder when it is imported. If this .bak file is placed in any other location (Desktop, CD-Rom, etc.), DL-Windows will be unable to...
View Answer
Answer:
After Discovering a lock, you will be prompted to "Link/Assign" this lock to an available Lock Profile previously created. If the Available Lock(s) By Serial Number field becomes blank when clicking on a Profile, it means that there are no Discovered...
View Answer
Answer:
The ArchiTech series N90 (cylindrical) N95 (mortise) support the iLock Bluetooth app. The model number must contain the letter J (N90J or N95J) or T (N90T or N95T) to indicate that the Bluetooth option is present.
...
View Answer
Answer:
Currently the ArchiTech model # N95J1 supports the iLock Bluetooth app. Note: You cannot upgrade an existing Networx or ArchiTech lock in the field. The integral Bluetooth receiver is installed only at the factory and cannot be...
View Answer
Answer:
No, an RR-RECEIVER is not necessary to pair the RR-1BUTTON to a NETWORXPANEL because the NETWORXPANEL already has a receiver built into it. To pair the RR-1BUTTON to a NETWORXPANEL, a NETDK or NETPDK locking device must be wired to the system,...
View Answer
Answer:
When programming the RR-1BUTTON to be used with a NETWORXPANEL, the main ("primary") relay always activates first, usually bypassing the auxiliary relay unless otherwise programmed to do so.
...
View Answer
Answer:
After the lock has been physically defaulted, proceed as follows:
...
View Answer
Answer:
As with most upgrades, the potential for data loss always exists. We therefore strongly recommend that prior to upgrading your Lenel OnGuard software, you always back up the following configuration file:
...
View Answer
Answer:
No, the operational modes and current draw specifications of the ArchiTech series control units are only designed to be used with ArchiTech series hardware. The only Networx-compatible product designed to control an electric strike or magnet is...
View Answer
Answer:
Other than checking the batteries for adequate voltage, remove the lock from the door and inspect the ribbon cable for damage. A damaged ribbon often causes a short on the battery connections, drastically decreasing battery life.
View Answer
Answer:
The versatility of the Alarm Lock Networx system allows the Gateways and wireless locks to communicate over many different types of networks. For this reason, it is always a good idea to “bench test” the equipment in a controlled...
View Answer
Answer:
Leave this selection blank, as the Gateway will automatically select an available channel.
View Answer
Answer:
DL-Windows software allows you to connect your PC with your lock. Although DL-Windows cannot make your lock a wireless lock; however, the following locksets have wireless capability:
...
View Answer
Answer:
To move Existing Networx Account Files to a New Computer, follow the steps below:A. COPY Your EXISTING ACCOUNT FILES
...
View Answer
Answer:
By default, shorting the two Remote Input wires allows passage by unlocking the above referenced lock models for the duration of the programmed Pass Time. To program the lock to remain unlocked for as long as the Remote Input wires are shorted,...
View Answer
Answer:
When an Alarm Lock Networx Gateway cannot be discovered by DL-Windows, either during initial set-up or after defaulting any Gateway, the solution is to verify that DHCP is enabled, as follows:
...
View Answer