Results Per Page | Showing
1-40 of 1895 Results
| 1 |
2
|
3
|
4
|
5
|
6
|
7
|
8
|
9
|
10
|
11
|
12
|
13
|
14
|
15
|
16
|
17
|
18
|
19
|
20
|
21
|
22
|
23
|
24
|
25
|
26
|
27
|
28
|
29
|
30
|
31
|
32
|
33
|
34
|
35
|
36
|
37
|
38
|
39
|
40
|
41
|
42
|
43
|
44
|
45
|
46
|
47
|
48
Answer:
Yes! Function 51 provides various ways to allow selected users to easily enable and/or disable Passage Mode. Specifically, Function 51 allows you to select how the lock responds to other available Passage Mode options such as Functions...
View Answer
Answer:
The DL-Windows V5.5.4 Schedules screen allows you to select Events that can be linked to pre-scheduled days and times. Shown below is a list of available Events from which you can select. This list applies to Trilogy locks that are not...
View Answer
Answer:
Yes. To allow a Trilogy Exit Trim lock to work with a Precision 2100 rim exit device, replace the factory Precision backplate with a "Backplate Center Driven Cam" adapter plate (purchased separately through Precision, part # BP21, shown...
View Answer
Answer:
Log in to the FireLink Cloud Programming Portal (www.FireLinkPro.com). In the portal Home screen:
...
View Answer
Answer:
Loop Response is the amount of time that a normally-closed circuit must remain open (or a normally-open circuit must remain closed) to trigger an alarm. The longer ("slower") the loop response time, the more immune the system will be to false...
View Answer
Answer:
When Supervisory Alarm Auto Reset is enabled, if a Supervisory zone is activated, the supervisory "SUPV" icon and keypad sounder automatically reset when the condition clears. To program this feature in the FireLink Cloud programming portal...
View Answer
Answer:
Yes! When a fire alarm activates, the Heating, Ventilation, and Air Conditioning (HVAC) system is generally required to be shut down to prevent the spread of smoke and fire. After a fire alarm-triggered shutdown, the HVAC system does not...
View Answer
Answer:
Yes. Launch PCD-Windows Quickloader, open User Assignment > User/System Codes, select the user that you want to assign to multiple areas. As shown in the example below, Mike is User #1 and as manager he has programming abilities and...
View Answer
Answer:
Yes. As shown below, launch PCD-Windows Quickloader, open NAC/Output Assignment > NAC/Output Options and add a check to Horn/Strobe Simultaneous Silence.
View Answer
Answer:
Yes. To have the siren sound momentarily (for 4 seconds) upon arming, launch PCD-Windows Quickloader software and:
...
View Answer
Answer:
Yes. As shown in the diagram below, cut the jumper "A" to change the control panel Aux Relay into a dry Class C relay.
...
View Answer
Answer:
MVP Access uses the following outbound ports for communication:• Port 5052 – Panel Communication• Port 5072 – Wireless Gateway Communication• Port 6072 – Mobile Link Communication
...
View Answer
Answer:
When updating the StarLink Communicator firmware, the option Smart Download is available:
...
View Answer
Answer:
The Gemini GEM-P3200, GEM-P9600, or GEM-X255 burglary alarm control panels can be programmed to provide a voltage trigger or a dry contact closure using a low current relay. This relay can be used to trigger your water valve controller to close...
View Answer
Answer:
The wiring shown below permits multiple relays to allow power through to the same output if any one of the wired relays is tripped.
View Answer
Answer:
NFPA 72 and UL 864 prohibit remote downloading to a Fire Alarm Control Panel unless a qualified technician is physically at the control panel installation site. To ensure a technician is on site, the Fire system keypad must first be unlocked...
View Answer
Answer:
Yes, all Prima systems must be activated, including 'demo' units. The Prima Super Panel must be activated on the www.NapcoComNet.com website to receive the latest firmware updates and to accept enrollments of sensors. The Prima unit is...
View Answer
Answer:
Yes, a Prima fire system in alarm requires a Master passcode to clear the alarm condition. The Master passcode is required and cannot be changed in the system Settings.
...
View Answer
Answer:
On the Prima PFOB Multi-Button Keyfob, shown below, to send an SOS signal you must press the red SOS button twice within 5 seconds. Upon the first button press, the blue LED at the top will illuminate, then press the SOS button again to send...
View Answer
Answer:
If your Prima is connected through the cellular network only, the RSSI (Received Signal Strength Indicator) is displayed in the Prima Portal under SYSTEM. The RSSI Level History is located near the bottom of the web page. An acceptable...
View Answer
Answer:
When looking at a Prima camera's Wi-Fi Signal Level and Wi-Fi Link Quality, it might be helpful to visualize these numbers using a number line:
...
View Answer
Answer:
Yes. To run reports in the Prima Portal:
...
View Answer
Answer:
When updating the Network Board's firmware to the MVP cloud version, in uniVerse Finder, if the user changes the Operation Mode to "Mode A" before attempting the firmware update, the update will not proceed. The Operator must switch the mode back to...
View Answer
Answer:
When discovering Gateways, Expander and Locks you must be on the CA4K Host Server, as a workstation, will not allow wireless services to stop and run.
View Answer
Answer:
When using dual path reporting and Simultaneous Dual Report is enabled, two signals are sent at the same time: One signal is sent through the cellular network and the other is sent using TCP/IP.
...
View Answer
Answer:
Open the NAPCO NOC (StarLink Radio Management Center) at www.NapcoNOC.com, open the communicator you wish to update and proceed as follows:
...
View Answer
Answer:
To set the control panel date and time using the GEM-RP1CAe2 or GEM-K1CA keypad:
...
View Answer
Answer:
Note: For workstations running the EPI, ensure that the .NET Framework 3.5 is enabled
View Answer
Answer:
Communication Cable for CICP1300IOCOMBO Board
...
View Answer
Answer:
To program a "Panel Relay Fire Trouble Relay" to monitor the status of the relays within the fire alarm panel (terminals 10, 11, and 12) to trigger a trouble signal by a loss of power:
...
View Answer
Answer:
To trip ("test") the GEMC heat detectors:
...
View Answer
Answer:
If a "Could not connect to port, Port in use!" message appears when using PCD-Windows Quickloader software, it is possible your modem COM port might be assigned to the same COM port used for the PCI2000/Mini PC interface. To verify the assigned...
View Answer
Answer:
V1.5.0.8 or later supports CICP1300NETBD2 (For CICP1300), CICP2800NETBD2 (For CICP2800), CICP2100/CICP2100S, CA-1, CA-2
...
View Answer
Answer:
Yes, the keypad will be disabled ("locked-out") after a programmable number (1-9) of unsuccessful User Code entry attempts for a programmable time period (1-60 seconds). By default, after six (6) failed credential attempts, Trilogy T3 door...
View Answer
Answer:
In addition to the instructions provided, the following may be helpful:
...
View Answer
Answer:
Yes! With cylindrical lock models such as the DL2700, DL2700LD, DL2800, DL3000, PDL3000, DL3200, DL4100, PDL4100, you will require a set of spacer plates, call 1-800-ALA-LOCK and order part # S6072, shown below:
View Answer
Answer:
Yes. The double-sided stand-alone door locks provide controlled entry and controlled exit at locations such as airport security areas and police stations. Both sides of the lock contain keypads, keyholes and levers. To differentiate...
View Answer
Answer:
Each User Code is assigned to a 'Group'; Schedules control the Groups.
...
View Answer
40 Results Per Page | Showing
1-40 of 1895 Results
| 1 |
2
|
3
|
4
|
5
|
6
|
7
|
8
|
9
|
10
|
11
|
12
|
13
|
14
|
15
|
16
|
17
|
18
|
19
|
20
|
21
|
22
|
23
|
24
|
25
|
26
|
27
|
28
|
29
|
30
|
31
|
32
|
33
|
34
|
35
|
36
|
37
|
38
|
39
|
40
|
41
|
42
|
43
|
44
|
45
|
46
|
47
|
48