How can I move a single account in DL-Windows 5.x.x to a different PC?

Answer:
In DL-Windows, select Tools > Export Account.  Save the .acc file to a USB thumb drive, then insert that thumb drive into the other PC.  Install DL-Windows into the other PC, open DL-Windows and select Tools > Import Account.

In the Air Access cloud, why are my edits and other changes not being saved?

Answer:
Be sure to use a compatible browser when using the Air Access cloud such as Microsoft Edge, Google Chrome, and Mozilla Firefox.  Use of other non-standard browsers could prevent the saving of modifications. 

When a (P)DL4100 or (P)DL4500 "Privacy" door lock is in use with Privacy mode engaged, will Administrative User Codes override (i.e., "bypass") Privacy mode to allow access through the door?

Answer:
When a (P)DL4100 or (P)DL4500 "Privacy" door lock is in use with Privacy mode engaged, remember that all Administrative User Codes will override (i.e., "bypass") Privacy mode to allow access through the door.  By design, all Administrative User...

I discovered and connected a factory fresh Alarm Lock ArchiTech Networx lock to an Air Access cellular access control system. Can this lock be changed back to its original factory default state?

Answer:
Factory default Alarm Lock devices such as Networx locks, readers, the NETWORXPANEL, etc., that have been discovered and connected to an Air Access system cannot be reverted to their original factory firmware.  The Air Access discovery and...

How do I set up my StarLink SLE-MAX2-series communicator for Dual Sim supervision?

Answer:
To set up your StarLink SLE-MAX2-series communicator for Dual Sim supervision, review this informative video:
...

Can you help me troubleshoot DL-Windows connection issues?

Answer:
Troubleshooting DL-Windows Connection Issues:
...

How do I set up a new Prima security system?

Answer:

-----------------------------------------
...

With my SLE-MAX2 Fire communicator, how do I enable "Super Dual" supervised dual path, dual carrier reporting?

Answer:
1.  Register the SLE-MAX2 series Fire communicator at the ComNet website (www.NapcoComNet.com) and select a Super Dual plan.
...

If I use a Gemini C-Series (GEMC) control panel as a "Burg-only" control panel, do I have to add resistors to all NAC circuits?

Answer:
Yes.  As shown in the image below, if you are using a Gemini C-Series (GEMC) Control Panel as a "Burg-only" control panel, you MUST add resistors to all NAC circuits as they are all supervised.  Remember, Area 1 will always be a Fire Area,...

Is an IP receiver needed to program a dual path StarLink communicator for reporting over a network (for primary) and cell (for back up)?

Answer:
No.  Network reporting is not required to program an IP receiver.  In addition, network reporting only exists between the communicator and the NOC (before the report is transferred to the central station). 

Is there a wiring and programming method to allow my FACP to use its two telephone connections (primary and secondary) for supervision and central station reporting through the StarLink SLE-MAXVI-FIRE communicator?

Answer:
Yes, by removing the JP2 shunt and enabling the feature "Tip/Ring Wiring Fault Report", when any communicator trouble is detected, the StarLink communicator will remove voltage from the secondary telephone output, triggering the FACP to locally...

How can I test the programming of an existing Test Timer feature?

Answer:
To test the programming of an existing Test Timer feature:
...

Is there an easy way to sequentially add a 'block' of proximity cards into DL-Windows?

Answer:
When adding proximity cards to DL-Windows, a Sequential Add utility is available if you have a block of cards you wish to add in sequence.  For example, card numbers 1093600 through 1093700 with all other card attributes (Card Type, Card Number...

Can an Air Access Communicator connect to an Air Access Gateway through an existing customer access point?

Answer:
No, an access point cannot be used within the Air Access system.
...

I want to program a door lock using DL-Windows or my AL-DTM Data Transfer Module, but the transfer speeds with my AL-PCI cable and USB-to-Serial adapter are too slow or are interrupted mid-transfer. What can I do?

Answer:
The AL-PCI is an interface cable that allows for high-speed communication between a PC running DL-Windows software and a compatible Trilogy Digital Lock or an AL-DTM Data Transfer Module.  Using the AL-PCI cable, the PC can upload or download...

I am installing an FACP that only supports SIA format; it is locked-out and requires special programming to change the reporting format. Do the StarLink SLE-MAX2-series communicators have an automatic SIA to CID conversion feature?

Answer:
Yes!  StarLink SLE-MAX2-series communicators support a SIA to CID conversion feature, where the communicator will automatically convert SIA format reporting codes to CID formatted codes.  In addition, SLE-MAX2-series communicators...

How to setup an Event Action for a Door Held Open

Answer:

Go into Settings > Device Settings and select Aux Output. Select which Aux Output you are using, and press Edit.  Under mode, set it to single pulse mode and then provide the time you want the output to be abnormal.  Press Save
...

If a Fire trouble on a 2-wire smoke loop will not clear, are there recommended troubleshooting steps I can perform?

Answer:
If a Fire trouble on a 2-wire smoke loop will not clear, the following troubleshooting test can be performed: 
...

Is there a third-party repeater or other wireless device that can be used to extend the range of my GEM-RECV wireless receiver?

Answer:
The Gemini series control panels support multiple wireless receivers to provide extended coverage when required.  Please add an additional receiver, positioned to extend the range of your GEM-RECV wireless receiver.

What is the Zone ANDing feature and how do I enable it with my GEM-P3200, GEM-P9600, and GEM-X255 control panels?

Answer:
With Zone ANDing, up to 8 groups of at least two zones each can be "AND"ed, wherein the system will go into alarm only if any two zones of the group are tripped within 2 minutes.  Zone ANDing is designed to afford redundant protection for...

Changing the default Formats in E-Access and Napco E-Access

Answer:
When a new card format is needed, it is suggested to create a new format by using the decoder and use that new format, in order to meet your card requirements. Do not edit one of the default card formats, as changing the default preloaded formats may...

I’m unable to communicate with my E-Access controller and it doesn’t seem to be taking the programming.

Answer:
Make sure the Status LED is blinking on and off, indicating proper polling of your IP Network.  If it’s not blinking on and off, power cycle the controller first.  If it’s still not working, verify a proper Static IP address was...

How do I test a wireless CO detector?

Answer:
Although depressing the recessed Test button for approximately 2 seconds will sound the device, to test if the detector senses the presence of carbon monoxide you must introduce a small amount of carbon monoxide into the detector.
...

How do I prepare PCD-Windows Quickloader software to communicate with my NAPCO control panel when using a telephone line (POTS)?

Answer:
Unlike other communication methods, communicating using a POTS ("Plain old telephone service") requires that you first establish a connection between the Quickloader software and the control panel before all transfer operations are enabled and...

With the Gemini control panel models GEM-P1632, GEM-P1664, GEM-P3200, GEM-P9600, and GEM-X255, can two Areas with a single alarm system share the same entry door zone?

Answer:
Yes, a zone can share two or more Areas (within the maximum number of Areas available consistent with the control panel model).
...

Why doesn't my Gemini or Magnum Alert MA3000 control panel indicate a trouble immediately after I disconnect the battery leads?

Answer:
If you disconnect one or both battery leads inside a Gemini or Magnum Alert MA3000 control panel, the low battery indication may take up to 4 hours to annunciate at the keypad.  This delay is because the control panel may require up to 4 hours...

I have StarLink 3G GSM Communicators that are still operational and in use. Do I need to hurry and upgrade them?

Answer:
Yes!  The AT&T 3G Sunset took place on February 22, 2022, and all StarLink Dealers were advised to replace any affected GSM communicators by this date.  The fact that a GSM communicator still appears to be functioning does not imply...

What type of wireless network does the SLE-WIFI-MODULE Wi-Fi module support?

Answer:
The SLE-WIFI-MODULE only supports the 2.4GHz Wi-Fi network.

Why is the error check utility in PCD-Windows Quickloader not allowing my Gemini control panel download to continue?

Answer:
Some older (version 9, 10, 11) Gemini control panels, including the GEM-P1632, GEM-P1664, PCD-Windows Quickloader to display an error on zone 9 when using Zone Doubling.   The solution is to disable the Error Check utility, as follows:
...

How do I communicate with my Alarm Lock Trilogy T3 lock using a computer?

Answer:
Enable PC uploading / downloading using Function 58, "Upload/Download PC Data", as follows:
...

What is an Ambush Code and which Trilogy T3 locks are equipped with a programmable Ambush Code?

Answer:
An Ambush Code is a special code entered at the lock keypad when a user is forced to unlock a locking device. The device unlocks but sends a silent alarm (with no indication at the keypad). The Ambush Code can be used to trip a relay, to alert...