How do I program the FWC-FSLC-SCH Smoke, Co and Heat Detector using the FireLink Cloud (www.firelinkpro.com)?

Answer:
Important:  The control panel firmware version must be V91.21 or later.  In addition, the GEMC-FW-SLC Fire SLC circuit board firmware version must be V4.4 or later; for GEMC-FW-SLC update instructions, see this link: ...

Is my StarLink communicator currently active or inactive?

Answer:
To verify the real-time status of your StarLink communicator, visit the NAPCO NOC website at www.NapcoNOC.com.  Although the communicator "Status" may be "Running Properly" (powered and working correctly), the SIM Status will indicate whether...

How do I map a GEM-WP single-button emergency pendant transmitter to a zone, and why is it important that I do so?

Answer:
The GEM-WP is a single-button emergency pendant transmitter designed for portability but can also be used as a stationary panic button.  To ensure the system correctly identifies the user who pressed the panic button (using Contact ID) and...

Do I need to install an FW-RM1 reversing module when connecting a Firewolf FW-2S smoke detector to a fire alarm control panel?

Answer:
You need a FW-RM1 reversing module when connecting a Firewolf FW-2S smoke detector with a sounder base; no reversing module needed when omitting the sounder base. 
...

Can I use any of the GEMC control panel zones (1-8) if there is a GEMC-F8ZCPIM Conventional 8 Fire Zone Expander Plug in Module ("FIM module") installed for conventional zones?

Answer:
No, the control panel may utilize zones 1-8 on the FIM module or in the SLC loop, but not both, as the control panel will be unable to determine where the zone is located.  With FireLink control panels, there are 2 options:  
...

How do I use horns and horn/strobes with the GEMC and FireLink FACPs?

Answer:
When using horns or horn/strobes with the GEMC and FireLink FACPs, you must use a NAC that is not used by other (non-CO) zones.
...

How do I enable the Fire Aux Relay to trigger when there is a fire alarm or trouble?

Answer:
Program for dry contact to change state when a fire alarm or a panel trouble condition occurs.  The following is for an additional annunciation panel (not a keypad):
...

My NAPCO Prima system is indicating a Contact ID code of "E412"; what does this mean?

Answer:
The definition of a Contact ID code E412 is "Remote Download, Access Successful".  This simply means that the Prima system has successfully completed a firmware update.

In the Prima dealer portal website (www.NapcoPrima.Pro), am I able to delete the Master User?

Answer:
Although you can delete the Master User in your Prima system, we strongly advise that you never do so.  The presence of the Master User is required by the Prima database to allow all other Users (User IDs) and Panel Codes to exist. ...

I’ve added cameras to my existing Prima Service Plan, why are the cameras not appearing in the Prima dealer portal website (www.NapcoPrima.Pro)?

Answer:
Adding cameras to an existing Prima account must be performed at the NAPCO ComNet website (www.NapcoComNet.com).  After making the changes in ComNet, it takes about 15 minutes for the changes to be pushed over to the Prima dealer portal.

Why didn't my control panel detect the loss of AC power?

Answer:
It is likely that the System Option "Disable AC Fail Detection" was enabled, thus the loss of power was ignored.  To enable AC fail detection:
...

When attempting to open PCD Windows Quickloader, why does a warning popup appear that states "Unable to open the desktop database. Please contact the administrator"?

Answer:
There is already an instance of Windows Quickloader running on your PC, likely minimized on your Taskbar.  Note:  After selecting OK in the popup, a new "Unable to Continue, Database Error!" message appears.

For UL Listed Burglary installations, how do I program a NAPCO Gemini control panel to annunciate a StarLink communicator trouble?

Answer:
In UL Listed Burglary installations, the control panel keypad must annunciate when the StarLink communicator goes into trouble, not solely when there is Telco line trouble or a 'fail to communicate' trouble.
...

How do I program Inputs 1 & 2 on an FWC-FSLC-EZM2 using the FireLink Cloud?

Answer:
The FWC-FSLC-EZM2 Dual Input Monitor Module is an addressable SLC two-zone conventional input module providing two independent contact monitoring circuits while only utilizing one address on the SLC loop.  Designed to be used with pull stations,...

In place of using the NL-MODCONFIG software, does the IBR-ZREMOTE have a browser interface where I can directly program its keypad address and IP information, etc.?

Answer:
Yes, the IBR-ZREMOTE can be optionally programmed using a browser in place of the NL-MODCONFIG software, as follows: 
...

Why did PCD-Windows Quickloader suddenly disallow the programming of fire options in my GEMC control panel?

Answer:
After the first download to a GEMC control panel, PCD-Windows Quickloader will lock out fire programming abilities to ensure the integrity of the AHJ approved fire program configuration and protect against inadvertent downloads.  To allow for...

How do I test my Gemini control panel digital dialer to ensure my alarm system is communicating with the central station?

Answer:
In PCD-Windows Quickloader software, select System Assignment > System Reporting and Outputs tab.  Add a check to the Test Timer option for Report on Alarm Telco 1:
...

What is the battery "derating factor" on the control panel Battery Standby Current calculator sheet?

Answer:
Battery degradation is the gradual loss of a battery's ability to store and deliver energy over time.  It is a natural process that happens to all batteries, and it is caused by a variety of factors, including:  
...

How many events can be stored in the NAPCO Prima system?

Answer:
In the NAPCO Prima Super Panel, the number of events stored depends upon the total file size of all events compared with the allocated storage space.  Events with images take up more storage space thus decreasing the total number stored.
...

Why is my Prima Camera not detecting vehicles and other motion?

Answer:
The Prima PCAM Indoor/Outdoor HD Camera and PBELL Wi-Fi HD doorbell camera are programmed to sense only human movement.  These cameras are intentionally programmed to ignore animals, vehicles, or other types of motion thus preventing the storage...

How do I silence the Prima voice annunciations that occur when arming and disarming?

Answer:
From the Prima main screen, tap MENU. Enter your Master (Dealer) Code: Tap Arming. Tap the function you wish to change, Staying or Leaving. Disable the voice annunciations as desired.

What is the Abort Delay security alarm system feature?

Answer:
The Abort Delay feature delays the reporting of a zone-trip alarm to allow for cancellation before the alarm report is sent to the central station.  For example, if a zone programmed for Abort Delay trips while the system is armed, the central...

Why does "Bad Phone Number" appear in the NOC Signal Log Response column?

Answer:
If you see "Bad Phone Number" in the Response column of your NOC Signal Log, ensure that the telephone number programmed in your control panel is a real receiver telephone number.
...

How do I change the IBR-TOUCH keypad type ('skin')?

Answer:

Place the control panel into configuration mode by placing jumper JP5 from the top two pins ("NORMAL") to the lower two pins ("CONFIG").
...

How do I wire a tamper switch to the metal enclosure of my StarLink communicator and program the input?

Answer:
Although each StarLink communicator housed in a metal enclosure is factory equipped with a tamper switch, the switch is non-operational by design; closing the enclosure door does not close the tamper switch.  If your installation requires a...

How do I set up my first Prima Super Panel?

Answer:
Setting up your first Prima account is simple.  Credentials that will allow you to access the Prima dealer portal website (www.NapcoPrima.Pro) will be emailed to you after activating your account on the NAPCO ComNet website...

Why is my newly installed wired doorbell not detecting motion?

Answer:
If your newly installed wired doorbell camera does not detect motion, first wait 15 minutes for the automatic firmware update process to complete.  Like many electronic devices, it is best to ensure the latest firmware is installed.  At the...

Does my Prima wireless camera automatically perform periodic status check-ins?

Answer:
The NAPCO Prima PCAM wireless camera and PWBELL wireless doorbell camera do not perform status check-ins.  Although both cameras each contain a 'heartbeat' that is used strictly for supervision to the Prima Super Panel, but the heartbeat does...

How do I delete an existing Prima account that appears in the Prima dealer portal website (www.NapcoPrima.Pro)?

Answer:
Perform the deletion in the NAPCO ComNet website (www.NapcoComNet.com). 
...

Why does the message ENTER YOUR CODE TO ACCESS AREA appear on my keypad display? Why won't the message clear after entering any User Code?

Answer:
The keypad message appears because the selection Remote Access Only was enabled in the PCD-Windows Quickloader Keypad Assignment screen.  When this selection is enabled, the selected keypad is changed to only accept Access codes and not arm /...

How do I print an 'AHJ Status Form' for fire devices on the SLC loop?

Answer:
In PCD-Windows Quickloader software, select Panel History > Status History. 
...

Why is my StarLink Communicator sending a network path failure (Alarm: Code 788, Area 00, Zone 2) signal in the NAPCO NOC after changing the radio data Service Plan?

Answer:

The network path failure code is due to the Service Plan being changed to a 'Sole Path' plan (in www.NapcoComNet.com) but the selection IP with Cell Radio Backup in the NAPCO NOC (www.NapcoNOC.com) was not changed (i.e., remained selected).
...

Does my NAPCO Prima installation require that it be monitored by a central station?

Answer:
NAPCO Prima installations do not require central station monitoring; however, the Prima system must still be registered at the ComNet website (www.NapcoComNet.com) and a service plan must be purchased in order to provide system notifications and...

How many zones does the Prima combination Smoke/CO detector (model 'PSMKCO') require?

Answer:
The PSMKCO Supervised Digital Wireless Smoke / Carbon Monoxide Detector uses only one zone in the Prima Super Panel.  The detector sends a different signal to the Super Panel depending on whether it detects a fire or carbon monoxide, therefore...

When will my new Prima account be visible in the Prima dealer portal website (www.NapcoPrima.Pro)?

Answer:
After a processing period of up to 15 minutes after registering a new Prima account on the ComNet website (www.NapcoComNet.com) it will become visible in the Prima dealer portal website (www.NapcoPrima.Pro). 

Does the strength of the Wi-Fi signal impact the battery life of the wireless Prima PCAM Camera or PBELL Video Doorbell?

Answer:
Wi-Fi connectivity issues may result in decreased battery life due to longer buffering times.  The minimum suggested Wi-Fi signal strengths for both the Prima wireless camera and wireless doorbell camera are:
...

What are the minimum required control panel firmware versions for use with the NetLink NL-RCM Remote Control Module?

Answer:
The following are the minimum control panel firmware versions that can be used with the NetLink NL-RCM Remote Control Module: 
...