Will the GEM-GB Glass Break Detector detect the break of laminated glass composites or multi-pane glass?
Below are the specs for the GEM-GB, including descriptions of the glass types and thickness the GEM-GB is capable of protecting. Please keep in mind that with any glass-break detector, if protecting multi-pane glass, both panes (inner and outer) must be broken in order for an alarm to be generated. Breaking the outer pane only may not generate an alarm.
SPECIFICATIONS
- Microphone: Electret, omnidirectional
- Temperature Range: 32°F to 120°F (0°C to + 50°C)
Range of Coverage (radius distance from sensor):
- Plate Glass, 25' (7.6m)
- Tempered, Wired, or Laminated Glass, 20' (6m)
Notes:
- Use 20' (6m) radius if unsure of glass type.
- If not using a Sentrol 5709-C Tester to verify range, reduce range to 15' (4.5m) for windows with blinds or unlined drapes.
- Reduce coverage 50% for armor-coated glass.
Glass Thickness:
- --Plate Glass, 3/32 to 1/4" (2.4 to 6.4mm)
- --Tempered Glass, 1/8 to 1/4" (3.2 to 6.4mm)
- --Wired Glass, 1/4" (6.4mm)
- --Laminated Glass, 1/8 to 1/4" (3.2 to 6.4mm)
- Dimensions: 3.13 x 4.24 x 1.7" (8.0 x 10.8 x 4.3cm) (H x W x D)