Results Per Page | Showing 1-12 of 12 Results
| 1
Answer:
While using Indala prox cards, the parity settings change over badge number 35,535. If you are using badge numbers below and above number 35,535, set the parity settings to zeros, and all badge numbers should work.
View Answer
Answer:
NO...
You can't have two formats in the CardAccess software with the same badge length.
View Answer
Answer:
The first and quickest thing is to Swap Data 0 and Data 1 lines right at the panel. After doing so, swipe the badge and see if this corrects the problem. If not, put the Data lines back to their original position.
View Answer
Answer:
Yes, but the feature must be turned on in the software license/security key. This is unlike the other controllers.
View Answer
Answer:
If Data 0 and Data 1 are swapped on the panel, the wrong number will display. Swap the data lines and see if the problem is resolved. If not, put them back to the way they were.
View Answer
Answer:
If the correct badge format is not in the CardAccess 3000 software, an alert will not display. You must verify the correct badge format is listed under "Administration>Badge Formats" for the badge to read.
View Answer
Answer:
Some PIV readers and PIV badges are dual technology. A dual technology PIV reader can read the PIV section of the badge and also read another technology in the badge such as 125KHZ. The reader will beep twice and the CardAccess 3000 will display...
View Answer
Answer:
1) The Continental 36 bit format part number is : C10202
2) Industry standard 26 bit format is : H10301
View Answer
Answer:
Unless you have the original packaging, it is very difficult to determine the exact badge format in the field. You have a few options:
...
View Answer