Results Per Page | Showing 1-7 of 7 Results | 1

How do I wire up an Accelaterm to repeat to another panel?

Answer:
Refer to the Accelaterm Service and Installation manual.
...

How do I wire up one 8 door panel to another 8 door panel using MULTI-DROP mode?

Answer:
VERY IMPORTANT: CONTINENTAL ACCESS RECOMMENDS USING REPEAT MODE. Multidrop has limitations including a 4000 feet limit  between the first and last panel, and a total of 9 panels in the multi-drop chain.
...

What cable do I use to wire up a modem to the CardAccess 3000 host?

Answer:
The Continental Modem cable is part # CI-RFQ0001. This cable can also be used for a Lantronix cable.
...

How do I wire up a Lantronix cable (UDS-10 and UDS-1100) to a Continental Controller (panel)?

Answer:
Warning: When you purchase a UDS-1100, you also receive a serial cable for programming purposes. This cable does not meet the specifications for connecting up to the Continental Controller. It is recommended to fabricate your own cable or...

How do I wire up a Continental polling cable to a Continental Controller (panel)?

Answer:
The Continental Polling cable contains 3 wires (purple, red and brown).
...

40 Results Per Page | Showing 1-7 of 7 Results | 1