How to setup Privacy Locks with Air Access & MVP Access Enterprise Access Control Systems

Answer:
Models:                     PDLN4100 / PDLN4500
...

Do I have to enable the keypad under Readers, to use a 26 bit keypad?

Answer:
NO... the keypad data received by the controller will be identical as a 26 bit Prox card. You do not have to Enable the keypad under Readers. 

If a reader is not reading on a specific reader port, can I measure voltages on the reader port to determine if I have a bad reader port?

Answer:
YES - Remove the reader wiring from the reader port. On the controller, you should read +5V between D0 to Gnd and 5V between D1 to GND. If you do not measure 5 volts, you will have to replace the board. 

Does the CA4K support a 4 or 8 bit burst keypad?

Answer:
YES - The CA4K will support a 4 or 8 bit burst keypad. In the early days of CA3000, it only supported a 4 bit burst, but eventually it was updated to support either a 4 bit burst, or a 8 bit burst keypad.     

What can cause a badge swipe not to read and not display an Alert/Event?

Answer:
If you are not using a keypad, you must verify the Keypad is NOT enabled under Readers>Door Control.  

What is the maximum amount of characters allowed on a Magstripe?

Answer:
 1) Max characters allowed on a Magstripe is 75 characters.
...

Why are my panels displaying"Door Open Too Long" Alerts when I am not using a door contact (sensor)?

Answer:
If you are not using Door Contacts (Door Sensors), you must set the Door Sensor =0 under Configuration>Readers and then you MUST perform a DATA DOWNLOAD to the panel. This requirement was added into the Continental Software in 2017. 

Can a XY matrix keypad be connected to an Accelaterm?

Answer:
NO...The Accelaterm does not offer an XY interface. Note: Most newer controllers do not support XY Matrix keypads.

When using the +5VDC Accessory power connector for readers, is the ground common with the reader port ground.

Answer:
Yes, the grounds are common between the +5V accessory power Connector and the Reader Port Ground.

How do you configure the TOGGLE mode in CardAccess 3000 and CA4K to lock and unlock doors using Continental Controllers (panels)?

Answer:
The Toggle mode (Single Swipe) for Relays is supported in the CardAccess 3000, V2.9.88 and V2.11.x. 
...

How do I configure Reader 2 in a Networx Panel?

Answer:
The Trilogy Networx Panel is a 1 Door (2 Reader) wireless controller. If both readers are used, they must be set up as IN/OUT readers (One on each side of the same door).
...

Why is the Continental Controller beeping when I connect up a keypad or reader?

Answer:
If there is too much power being drawn on the +12volts or +5volts, the Continental Controller will beep. If this occurs, remove the keypad or reader immediately.

What is the "Double Tap" feature for Wireless Locks with prox readers and Continental Controllers?

Answer:
The "Double Tap" feature works identical for Wireless Locks with Prox readers and Continental Controllers with the latest firmware as of V2.11.84 and all versions of the CA4K software. For this function to work, you must select "Double read holds...

How do I move CardAccess 3000 to a new computer including my current databases?

Answer:
VERY IMPORTANT: If possible, name the new computer the same name as the old computer name. This will eliminate some of the most difficult steps in this procedure.
...

What else can I try if my reader /keypad is wired and programmed correctly, and it's still not functioning?

Answer:
Like any electronic device, it's always recommended to cycle the power on the reader/keypad.

Why is my PIV card reading an incorrect number and also getting two reads?

Answer:
Some PIV readers and PIV badges are dual technology. A dual technology PIV reader can read the PIV section of the badge and also read another technology in the badge such as 125KHZ. The reader will beep twice and the CardAccess 3000 will display...

Are virtual inputs supported on the Accelaterm?

Answer:
Yes...Virtual Inputs are available on the 8 and 16 door Accelaterm. They are only available on the first 8 readers on both models (8 or 16 Door). The virtual input numbers for the first eight readers map identical to the Turbo Superterm and...

What is the Mapping for the Inputs on an Accelaterm (CICP2800) 8/16 door controller?

Answer:
Note: An 8 door Accelaterm can have up to 3 I/O expansion boards connected to it.  A 16 door Accelaterm can only have 2 I/O expansion boards connected to it. Each I/O expansion board contains 16 additional inputs and 16 additional...

What can cause a "Badge Violate Void At Panel" alert message to display?

Answer:
Summary: This error message means there is a record of the badge in the database, but the badge does not belong at any reader on the panel.
...

What can cause my reader/keypad not to function when I supply an external voltage source to it?

Answer:
When an external voltage is supplied to a reader/keypad, you MUST common the grounds between the power supply ground and the ground on panel.

What are the different modes for which I can configure a keypad?

Answer:
There are many types of keypads available, which determine the different modes available. Below are 4 different supported modes.
...

What can cause a photo not to pop-up with a valid card read and the option set to "Auto Show All"?

Answer:
For a photo to pop-up, the alert must be configured to come into the Alert grid (bottom half of screen). If the alert is configured to go directly to the event grid (top half of screen), the photo will not pop up. By default, valid badges are...

Why are my badges not working on a new panel recently added into the CardAccess 3000 or the CA4K software?

Answer:
The following are some reasons why this might occur after adding a new panel to the software"
...

After a door is manually locked, why is it going back into "Free Access" on the next valid card swipe?

Answer:
Verify the door sensor is working correctly. If there is no physical door contact, you MUST set the "Door Sensor" setting to zero under "Configuration>Readers>Door Control".