What are the three steps needed to install NAPCO's dealer-registered products, such as StarLink, iBridge, iRemote and Air Access devices?

Answer:
This video describes how to: 1. Become a registered dealer.2. Activate the device.3. Program the device.  

Do I have to register an iBridge IBR-ZREMOTE, iREMOTE-MOD or NetLink NL-MOD on the ComNet website (www.NapcoComNet.com) if I am using the device only for IP reporting sent directly to my central station?

Answer:
No, you do not need to register the device on the ComNet website if you are using an iBridge IBR-ZREMOTE, iREMOTE-MOD or NetLink NL-MOD only for IP reporting to the central station.

Can we take over (transfer) a StarLink communicator if the previous alarm company is out of business or the customer switches security alarm companies?

Answer:
The only way to transfer a StarLink communicator from one company to another is to perform a device transfer procedure in direct coordination with the NAPCO ComNet department. The previous company wishing to hand-off (release) the device must place a...

How do you replace an older iSeeVideo, iREMOTE-MOD or iBridge device without creating a new subscriber?

Answer:
Log in to www.NapcoComNet.com with your dealer information. Click My Subscribers (at the top of the screen, as shown below).
...

Which NAPCO products can I use to connect to my existing NAPCO control panels and upload and download programming information?

Answer:
There are several communication methods you can use to connect to your existing control panels: 
...

After downloading the IP address of the NAPCO NetLink Receiver located at my central station to my iREMOTE-MOD or IBR-ZREMOTE, I am no longer able connect to the module using the app. How do I fix this and prevent this from happening with future installations?

Answer:
In the NL-MODCONFIG software, open the PC preset/RCM tab, click the Populate NAPCO Defaults button and select the option for the module type you are working with.  Repeat the same steps for the Secondary/RCM tab then download to the module.
...

Using the PCD-Windows Quickloader "Panel Communications" screen, I want to upload and download to my Gemini control panel through an iREMOTE-MOD or NL-MOD. Should I select "NL-Mod" or "iBridge"?

Answer:
When using TCP/IP communications to connect to your Gemini control panels, note the following two options under TCP/IP Communications:
...

May I add an iREMOTE-MOD to a Gemini C-Series (GEMC) control panel burglary bus to allow access to a virtual keypad?

Answer:
Yes, the iREMOTE-MOD is compatible with the Gemini C-Series (GEMC) control panel, but with the Burglary area only.  A GEMC-BK1 Burglary keypad skin is available for use on the www.MyRemoteKeypad.com website and for the iRemote App.
...

I am unable to see my iBridge IBR-ZREMOTE, iRemote-MOD or NL-MOD using the NL-MODCONFIG software (v3.0.3.0 or later). What can I do?

Answer:
If you are unable to search for and find your iBridge IBR-ZREMOTE, iRemote-MOD or NL-MOD module(s) using the NL-MODCONFIG software (version 3.0.3.0 or later), perform the following:
...

Can you add an iRemote-MOD to a GEMC Burglary bus for a virtual keypad?

Answer:
Yes, the iRemote-MOD will operate with the GEMC Burglary section only (Note:  For non-UL applications only).  A keypad skin is currently available through www.myremotekeypad.com, however a keypad skin for the iRemote-MOD app will be...

I just registered a new iBridge / iRemote unit and when I log in through www.iBridgeOnline.com, www.MyRemoteKeypad.com or through my App and select the Security tab, no keypad is displayed. How can I resolve this?

Answer:

The "Keypad Type" was not selected during the first web log in process (Keypad Types are normally the GEM-K1CA or GEM-RP1CAe2).  In addition, ensure both CAT5 cables are securely attached, and the red LED is blinking every five seconds.
...

When I log into my iRemote-MOD, why does the message "Keypad Busy Try Again Later" appear?

Answer:
1.  Only one (1) user is allowed to be logged in at any one time.  If you are still logged in to your iPhone, Android or through the iRemote website, ensure you have logged out successfully.
...

My iRemote is displaying the "Old Compat" number, which I did not change. How do I change it back to "0000"?

Answer:
Try using 4444, 5555, 8888 or 9999 as your "Old Compat" number.  If these numbers do not work, then a "Compat #" must have been set in the past and cannot be defaulted.  Please contact Technical Service at 800-645-9445 or 631-842-9400 for...

What is the default username and password when creating a new subscriber account for iBridge, iSeeVideo and the iRemote-MOD?

Answer:
The default password is "1234", and the default username is automatically generated using the "first 3 characters" of the subscriber's first name and the "last 4 digits" of their Phone number.  For example, with the information shown in the...

With the iRemote-MOD, how many additional User IDs can be set up for a customer in one account?

Answer:
Up to five (5) User IDs are allowed per account.  One User is the Master, and the others are "standard" Users).  If you need more than five, contact Technical Support.

I want to connect the hardwired iBridge tablet (IBR-ITAB-HW) to a Gemini control panel and use the tablet as a keypad ONLY. Do I need an IBR-ZREMOTE or an iRemote-MOD?

Answer:
No, you do not need an IBR-ZREMOTE nor do you need an iRemote-MOD in order to connect the hardwired iBridge tablet (IBR-ITAB-HW) to a Gemini control panel and use the tablet only as a keypad.  NOTE: If you are using an IBR-ITAB wireless tablet,...

What port needs to be forwarded for the iRemote-MOD and for the NL-MOD if they are located behind a firewall?

Answer:
You will need to port forward ports 5002 and 5011 for the iRemote-MOD (select TCP or both TCP/UDP for the protocol) and port 5001 for the NL-MOD (select TCP or both TCP/UDP for the protocol).
...

Which port do I need to port forward to allow remote uploading and downloading through the NL-MOD / iRemote-MOD?

Answer:
Port forwarding (also called "port mapping") opens a specific port number in a router or firewall (in a private network) to allow network packets from the outside world with that port number to pass through. 
...

How can I control a programmable "set-back" thermostat via the iRemote-Mod?

Answer:
NOTE:  This pertains to Control Panels GEM-P1632 / GEM-P1664 v10 or greater, GEM-P3200 / GEM-P9600 v30 or greater, and GEM-X255 v4 or greater; and explains how to configure Area1 to control a set-back thermostat via the iRemote.

How can I display an iRemote at both the MyRemoteKeypad.com and VideoAlert.net sites?

Answer:
As a Dealer in MyRemoteKeypad.com and VideoAlert.net, you can assign your iRemote-MOD at both websites for customers who also have an ISeeVideo camera system.  This will give your customers the opportunity to use their iRemote normally at...

When I connect to my iRemote-MOD, I only get the message "NOT ALLOWED NOW, TRY AGAIN". How can I resolve this?

Answer:
After checking that the iRemote-MOD is configured correctly with the control panel as detailed in the installation instructions, use these troubleshooting tips if necessary:
...

When I attempt to arm my iRemote-MOD, the STAY and AWAY buttons do not work correctly on the K Style keypad template. How can I resolve this?

Answer:
After checking that the iRemote-MOD is configured correctly with the control panel as detailed in the installation instructions, use these troubleshooting tips if necessary:
...

When I connect to my iRemote-MOD, I get the message "01 (or 02,03,04,05,06,07) Out of System". How can I resolve this?

Answer:
After checking that the iRemote-MOD is configured correctly with the control panel as detailed in the installation instructions, use these troubleshooting tips if necessary:
...

When I connect to my iRemote-MOD, I can only get a blank display. How can I resolve this?

Answer:
After checking that the iRemote-MOD is configured correctly with the control panel as detailed in the installation instructions, use these troubleshooting tips if necessary:
...

Can you explain the iRemote-MOD Quick Start Instructions?

Answer:
1.   Wire the network connection from your iRemote-MOD to a valid Internet source on the network (for example, a router or switch to provide an access point).
...

How can I Install the iRemote or iSeeVideo App on my BlackBerry?

Answer:
Our Napco iSeeVideo www.videoalert.net and iRemote www.myremotekeypad.com websites both have mobile counterparts that you can install into a BlackBerry mobile device. 
...

What are the Gemini control panel firmware version requirements for use with the iRemote-MOD, NL-RCM and NL-MOD?

Answer:
The iRemote-MOD is compatible with all Gemini control panels regardless of the control panel firmware version installed when used only for Virtual Keypad access.  However, when using the NetLink TCP/IP communications feature for:
...

How do I update the firmware in the NL-MODCONFIG Software?

Answer:
To update the NL-MODCONFIG software, proceed as follows:
...

How do I supervise the connection status of the iRemote-MOD or NL-MOD should either be disconnected from the Internet?

Answer:
Connect a single wire from the "Supv." output terminal on the iRemote-MOD or NL-MOD to the positive (+) side of "ANY" zone with a 2.2k resistor in parallel.  The iRemote-MOD "Supv." output will go to low voltage upon losing its Internet...

Is the iRemote-MOD compatible with all Gemini control panels when using its remote "virtual" keypad capability only (its integral NL-MOD Network Communication Module reporting capability disabled)?

Answer:
Yes, the iRemote-MOD is fully compatible with the Gemini control panels listed below if using its remote "virtual" keypad capability only.  This includes User and Dealer programming (except for control panel version 9A in the GEM-P816 &...

The message "TCP/IP Communication Stopped" appears when PCD-Windows Quickloader software is used to remotely upload from (or download to) a control panel using an NL-MOD Network Communication Module or an iRemote-MOD Remote Control Module. What can I do?

Answer:

This message (see above) appears when the TCP/IP Communications feature is not enabled in the control panel program.  To enable in Quickloader, go to the Digital Communications screen, Digital/Dialing Options tab and check the "TCP/IP...

The message "Socket state: 9" appears when PCD-Windows Quickloader software is used to remotely upload from (or download to) a control panel using an NL-MOD Network Communication Module or an iRemote-MOD Remote Control Module. What can I do?

Answer:
The message "Socket state: 9" appears when the NL-MOD is unreachable by the IP address used.  This message can appear if the IP address is incorrect, if the NL-MOD is offline, or if there is a firewall preventing access on port 10081.  If...

The message "Invalid response received" appears when using PCD-Windows Quickloader software to upload from or download to a control panel using an NL-MOD Network Communication Module or an iRemote-MOD Remote Control Module. What can I do?

Answer:
The error "Invalid response received" appears (see image below) when the NL-MOD is reachable but communication does not exist between the NL-MOD and the control panel.  This can occur if the local download cable is disconnected or damaged, or if...

40 Results Per Page | Showing 1-40 of 45 Results | 1 | 2