How to enable .Net Framework 3.5 and 4.x?

Answer:
Note: For workstations running the EPI, ensure that the .NET Framework 3.5 is enabled

Is the FireLink / GEMC control panel Point ID reporting code "E300 area 00 Z1 A00" a Z1 trouble?

Answer:
Reporting code E300 area 00 Z1 A00 is a common FireLink or GEMC control panel Point ID reporting code that some central stations may mistakenly confuse with a Z1 trouble. 
...

Why is my Trilogy door lock constantly beeping after a battery change?

Answer:
When changing the batteries in your Trilogy lock, ensure the correct polarity with each battery.  If a battery is installed with incorrect polarity, the lock might seem to power up correctly but in fact will not receive the correct...

How do I reset the iSecure control panel back to its original factory default settings ("Cold Start")?

Answer:
Resetting the iSecure control panel back to its factory default settings ("Cold Start") will leave your iSecure panel with a blank program. We STRONGLY recommend that before you begin, that you first back up your panel program to the iSecure Cloud...

Where can I find information on EPI Badging?

Answer:
You will find many EPI documents in the Continental Document library. In addition, there are CA4K EPI Badging videos in the Continental Video library. 
...

Where can I find my EPI Badging templates in CA4K?

Answer:
In CA4K, the Badging template files (.dgn), do not have a descriptive name. They will have a unique number with the extension of .dgn. They can be found in the root of the CardAccess4K folder. Templates are also stored in the live configuration...

Can I have two badging stations on one CA3K or CA4k system?

Answer:
Yes, you would have to purchase two sets of EPI licenses (one set for each badging station).   

How do I disable Push Notifications in the iBridgeVideo app while keeping motion-triggered Cloud Recording active?

Answer:
To disable Push Notifications only, configure your smart device 'Settings':
...

Do all EPI templates and information migrate over from CardAccess 3000 to CA4K?

Answer:
YES...All the EPI information in the CardAccess 3000 database will migrate over to the CA4K database while executing the CA4K Migration utility. Even though all templates are stored in the database, it is highly recommended to manually copy over all...

With my model (P)DL4500 "Residential / Privacy" lock, how do I enable Total User Lockout Mode using the lock key cylinder?

Answer:
The "Privacy" feature allows access through the door to individuals with User Codes and is typically used for rooms needing privacy from others such as bathrooms, dorms, meeting rooms and sleeping rooms in hospitals.  When a model DL4500 or...

Can the CardAccess 3000 and CA4K be installed on the same computer?

Answer:
NO... All versions of CardAccess 3000 must be uninstalled from the computer prior to installing the CA4K. This includes uninstalling EPI Badging 3000. 

What operating systems is EPI Badging (EPI Builder) supported on while using CA3000 and CA4K?

Answer:
The version of EPI Builder in the CardAccess 3000 is version 6.3.x. This version of EPI is in the CardAccess 3000 V2.11.x and earlier. This version is not supported on Windows 8.1 Pro, Windows 10 Pro and Server 2012. This version of EPI...

What can cause a barcode that was generated in EPI to read intermittently?

Answer:
If a Barcode has a border or logo close to it, the ink from the border or logo might bleed off to the barcode and cause intermittan reads. Completely remove any borders or logos near the barcode and verify if the barcode reads...

If I purchased the EPI Canon license, where can I download the EPI Canon plug-in software from?

Answer:
The EPI Canon Plug-In can be downloaded from the EPI (Imageware Systems) website at the following link:   https://iwsinc.com/about/support/epi_builder/            

Why is the Continental Controller beeping when I connect up a keypad or reader?

Answer:
If there is too much power being drawn on the +12volts or +5volts, the Continental Controller will beep. If this occurs, remove the keypad or reader immediately.

On CA3000, what are the special configurations needed for EPI on a 64 bit computer?

Answer:
NOTE: EPI is not supported on Windows 8.1 Pro or Server 2012. If the CardAccess 3000 host computer is one of these operating systems, you should install EPI on a Windows 7 CardAccess 3000 Workstation.
...

What are the steps to move EPI Builder Licenses from one computer to another?

Answer:
VERY IMPORTANT - To execute any of the EPI Builder utilities (ex. Revoke, Activate...), YOU MUST RIGHT CLICK the utility and select "RUN AS ADMINISTRATOR".
...

On CA3000, why am I getting an error while starting the EPI Badging 3000 after a CardAccess 3000 upgrade?

Answer:
NOTE: EPI in the CardAccess 3000 is not supported on a Windows 8.1 or Server 2012 computer. If the CardAccess 3000 host is one of these operating systems, it is recommended to install EPI Badging on a Windows 7 CardAccess 3000 workstation.
...

Can I "zoom in" the iSeeVideo camera live picture?

Answer:
Yes, you can digitally "zoom in" the iSeeVideo camera live picture by clicking the "zoom in" or "zoom out" buttons (located above your live picture as shown by the arrow in the image below).  However, you must use a PC web browser with full...

Are there any security password recommendations that I should follow when using DL-Windows?

Answer:
Keeping a written record of your unique DL-Windows Security Password in a secure location is highly recommended under normal circumstances, and is even more important when upgrading DL-Windows as the Security Password must be re-entered into...

On CA3000, why are my EPI templates not displaying in Personnel when I try to select one?

Answer:
If you successfully Designed, Saved and Imported the template, it should display in Personnel under the "Photo" tab.
...

On CA3000, why am I getting an "Invalid Pointer" error while using Badging 3000?

Answer:
EPI Badging 3000 requires "MSXML 4.0". You must verify that this is installed. If it's not installed, you can download it from Microsoft.

What can cause errors while licensing the EPI runtime and EPI Designer licenses?

Answer:
Note: If the EPI licenses were previously used on another computer, the licenses must be revoked on the original computer and re-activated on the new computer. 
...

On CA3000, why is my template not displaying when I click "Preview" in personnel?

Answer:
Is this a new template or an existing template?
...

Where do I enable EPI Badging in the CardAccess 3000 or CA4K software?

Answer:
1) For CardAccess 3000, you must select "Badging3000" under "System>System Settings>Video Badging".
...

On CA3000, why is my photo not displaying in "Personnel" after it is imported in?

Answer:
There are multiple reasons that could cause a photo not to import into the CardAccess 3000.
...

What can cause the "Print" button not to display in "Personnel"?

Answer:
If the "Video Badging" setting under "System>System Settings" is configured for "Photos Only", the "Print" button will not display. You must purchase and configure the Badging3000 (EPI) software for the "Print" option.

Who do I call if I'm having a problem activating my Imageware EPI Badging licenses or I need licenses reset, while moving to a new computer?

Answer:
Unfortunately, you are unable to call EPI support anymore. You must fill out the EPI online support request form for license resets and license activation issues. After submitting the form, the EPI technical support team will call you. The support...

For Control Panels GEM-P816, GEM-P1632, GEM-P1664, GEM-P3200, GEM-P9600, GEM-X255: Normally, the system trouble audible indication at the keypad can be silenced by simply pressing the keypad Reset key. However, if no one is present to press Reset, can the keypad beeping upon a trouble condition be silenced automatically? My dog is greatly disturbed by the keypad beeping.

Answer:
By default, the system trouble audible indication at the keypad will sound for 10 minutes, or until the user presses the Reset key.  However, there is an option to eliminate the system trouble audible at the keypad in cases where pets or others...

Can I stop the burglary keypad from beeping every time the panel is arming?

Answer:
No this is required by UL in order to achieve SIA CP-01 compliance.  It cannot be switched off.

40 Results Per Page | Showing 1-32 of 32 Results | 1