Why do some E-Access configuration or update screens take a long time to load or show incomplete data?

Answer:
When the system is connected only through a switch and has no internet connection or router, certain screens—such as the update and configuration screens—may experience delays. This occurs because the system first attempts to reach the...

Can I arm and disarm a burglary alarm system after it is integrated into the NAPCO E-Access controller?

Answer:
After successfully integrating the NAPCO E-Access controller with a burglary alarm control panel (such as the Gemini GEM-P3200), the NAPCO E-Access controller can only disarm the burglary alarm.  The NAPCO E-Access controller cannot arm the...

How to setup an Event Action for a Door Held Open

Answer:

Go into Settings > Device Settings and select Aux Output. Select which Aux Output you are using, and press Edit.  Under mode, set it to single pulse mode and then provide the time you want the output to be abnormal.  Press Save
...

Changing the default Formats in E-Access and Napco E-Access

Answer:
When a new card format is needed, it is suggested to create a new format by using the decoder and use that new format, in order to meet your card requirements. Do not edit one of the default card formats, as changing the default preloaded formats may...

I’m unable to communicate with my E-Access controller and it doesn’t seem to be taking the programming.

Answer:
Make sure the Status LED is blinking on and off, indicating proper polling of your IP Network.  If it’s not blinking on and off, power cycle the controller first.  If it’s still not working, verify a proper Static IP address was...

Which readers and ArchiTech locks have Bluetooth capabilities and will work with the NAPCO E-Access system?

Answer:
The following readers and ArchiTech locks have Bluetooth capabilities and will work with the NAPCO E-Access system:
...

What are Continental E-Access "Threat Levels" and how are they used?

Answer:
THREAT LEVEL is a feature of the E-Access system that allows you to temporarily modify or bypass the existing Schedules and Access Level privileges.
...

What are NAPCO E-Access "Threat Levels" and how are they used?

Answer:
THREAT LEVEL is a feature of the E-Access system that allows you to temporarily modify or bypass the existing Schedules and Access Level privileges.
...

Is there an easy way to build an E-Access User database?

Answer:
Yes, the easiest way to add users to an existing User list, is to use the Export and Import features located in SETTINGS.
...

Is there an easy way to build a NAPCO E-Access User database?

Answer:
Yes, the easiest way to maintain your existing User list is to use the Export and Import features located in SETTINGS.
...

After my Remote Management Connector (RMC) is purchased and licensed, what can cause the RMC not to connect?

Answer:
After the RMC is licensed, you must go to SETTINGS and ensure the "CONNECT TO RMC" setting is set to ON, and the Network Status displays OK.

Is the Remote Management Connector (RMC) a standard feature in NAPCO E-Access?

Answer:
No, the RMC feature must be purchased and must be added to the license. After it is licensed, you must go to SETTINGS and ensure the RMC is set to ON, and the Network Status displays OK.

How do you enter facility codes into the NAPCO E-Access controllers?

Answer:
In NAPCO E-Access, the facility code is part of the badge format. If you have two 36-bit badges with different facility codes, you must enter two different 36-bit badge formats. The badge format includes the facility code.

Are E-Access strike relay numbers configurable?

Answer:
No. NAPCO E-Access strike relay numbers are fixed and cannot be changed.

After my RMC is purchased and licensed, what can cause the RMC not to connect?

Answer:
Once it is licensed, you must go to Settings > Network Settings > RMC and make sure the "CONNECT TO RMC" is set to ON, and the Network Status displays OK. 
...

Is the RMC (Remote Management Connector) a standard feature in CAE/NAE?

Answer:
NO, the RMC feature must be purchased and must be added to the license. Once it is licensed, you must go to SETTINGS and make sure the RMC is set to ON, and the Network Status displays OK. 

How do you enter facility codes into the CAE/NAE controllers?

Answer:
Unlike the Continental software where there is a facility code screen, in E-Access, the facility code is part of the badge format.
...

Are E-Access strike relay numbers configurable?

Answer:
NO - CAE/NAE strike relays numbers are fixed and can't be changed.

Why is my NAPCO E-Access RMC shortcut no longer working?

Answer:
When you create a shortcut for RMC, do not use the URL from the "Secure Link" in RMC. If you do use this URL, the port number will change, and the shortcut will no longer work. The proper way to create a shortcut for RMC is to go into RMC > Device...

Why is my E-Access RMC shortcut not working anymore?

Answer:
When you create a shortcut for RMC, do not use the URL from the "Secure Link" in RMC.   If you do use this, the port number will change and the shortcut will not work anymore. The proper way to create a shortcut for RMC, is to go into...

What is the maximum size SD-Card NAPCO E-Access controllers support, and what is the format?

Answer:
The NAPCO E-Access controllers support up to a 16 Gig SD-Card, formatted with FAT32.

What is the maximum size SD-Card Continental E-Access controllers support, and what is the format?

Answer:
The Continental E-Access controllers support up to a 16 Gig SD-Card, formatted with FAT32.

What is the maximum amount of users the NAPCO E-Access controller supports?

Answer:
The maximum amount of users supported is 5 users for a Basic license, and 10 users for the Advanced license.

What is the maximum amount of users the Continental E-Access controller supports?

Answer:
The maximum amount of users is 25, for a Continental E-Access license. 

How do I download a Napco E-Access Mobile Credential using the Sicunet "Open Cesame App"?

Answer:
Note: The "Open Cesame" App is not posted under Napco Security Technologies yet. 
...

Is there a Napco E-Access Mobile App available?

Answer:
As of October, 2022, the Napco E-Access Mobile App is not available yet. Please check with the Napco Technical Support group, to find out if it's available yet.  

How do I download the license to a new E-Access controller?

Answer:
Upon logging in, the license screen will display. Click Edit and the MAC address should display, and the rest of the fields will be blank. If the controller is a Server, click the "Server Key" button. If it's going to be a Client, click the "Client...

What can cause a badge to be denied at a reader in Napco E-Access?

Answer:
When configuring a badge in E-Access, you must apply an Access Level to the badge. On the screen where you apply the Access Level, the TYPE should display "INDIVIDUAL". If TYPE is configured for "Access Level Group", there is more chance of having a...

If I have a bad Napco E-Access controller, how do I swap the license to a new controller?

Answer:
To swap the license from the defective controller to a new controller, you must use the "Swap Key" function. This allows you to transfer the license key from one Controller or panel to another.
...

If I am unable to login to the Napco E-Access Mobile Application, what can be the problem?

Answer:
The Napco E-Access Mobile App username and password is case sensitive. Please verify you type in the Username and Password with the correct case (Capital or lower case characters).

In Napco E-Access, can you have an INPUT unlock a door?

Answer:
Yes, you can configure an INPUT to unlock the door.  First, go to settings and define your inputs under the device settings, next go to settings, Event Action, click on Event Action and create your action there.

What is the least amount of Doors a Napco E-Access license can have?

Answer:
The license is available with 32 or more doors. 

Can you export out of one Napco E-Access unit and Import the data into another Napco E-Access unit?

Answer:
Yes...Napco E-Access offers an Export utility and an Import Utility. 
...

How do I download the "Open Cesame" Mobile Credential App?

Answer:
Note: As of October 2022, the "Open Cesame" App is not posted under Napco Security Technologies yet. 
...

Are 4 bit and 8 bit keypads supported in E-Access?

Answer:
NO...Only Weigand Keypads are supported and they require a badge format in the E-Access software.

Are 4 bit and 8 bit keypads supported in E-Access?

Answer:
NO...Only Weigand Keypads are supported and they require a badge format in the E-Access software.

What can cause an "Access not Complete" message after a card swipe?.

Answer:
You need to make sure that if there are door contacts, that the person needs to complete the action and open the door. To avoid event, do not use door contacts.

How do I use Card and Pin in Napco E-Access?

Answer:
You need to create the keypad format under Card Formats, and assign it in the Doors screen.  The steps for Card and Pin starts with Pin first then card swipe.  Very Important - The reader and keypad need a badge format for each.

How do I read a Card (badge) format in Napco E-Access?

Answer:
Swipe the badge at a reader. In the event grid, click on the "Card Format Not Found Blue link". This will then bring you to the badge format screen to create the missing badge format.
...

40 Results Per Page | Showing 1-40 of 70 Results | 1 | 2