How do I configure the Shunt Relay option of the NETWORXPANEL when it is connected to my Air Access system?

Answer:
To use the AUX relay of a Trilogy Networx™ System NETWORXPANEL Wireless Networx Control Panel that is connected to an Air Access system, configure the Shunt Relay option as follows:
...

I discovered and connected a factory fresh Alarm Lock ArchiTech Networx lock to an Air Access cellular access control system. Can this lock be changed back to its original factory default state?

Answer:
Factory default Alarm Lock devices such as Networx locks, readers, the NETWORXPANEL, etc., that have been discovered and connected to an Air Access system cannot be reverted to their original factory firmware.  The Air Access discovery and...

Will the Air Access system work with Alarm Lock model NETPDK or NETDK keypads?

Answer:
No, Air Access requires Wiegand readers only. Order any of the compatible readers offered by Alarm Lock, listed below. Do not order Networx DK Panel Packs as the NETPDK and NETDK model keypads are not compatible with the Air Access system. Order the...

Can I use a standard Generation 3 Alarm Lock Gateway (e.g., model AL-IM3 series) with an Air Access system?

Answer:
No. The Air Access system requires Air Access system Gateways. The model AA-GATEWAY, AA-GATEWAYPOE or AA-GATEWAY-PW must be used. Note: The Alarm Lock model AL-IM3 is used with DL Windows, Networx and Continental. Refer to the instructions included...

Can I use the new Version 3 Gateways (AL-IM3-80211 and AL-IM3-POE) with Air Access?

Answer:
No.  The new Networx Version 3 Gateways (AL-IM3-80211 and AL-IM3-POE) are only for use with the Continental Access CA4K software and the Alarm Lock DL-Windows software. 
...