Why are my panels displaying"Door Open Too Long" Alerts when I am not using a door contact (sensor)?

Answer:
If you are not using Door Contacts (Door Sensors), you must set the Door Sensor =0 under Configuration>Readers and then you MUST perform a DATA DOWNLOAD to the panel. This requirement was added into the Continental Software in 2017. 

When using the +5VDC Accessory power connector for readers, is the ground common with the reader port ground.

Answer:
Yes, the grounds are common between the +5V accessory power Connector and the Reader Port Ground.

What is the Mapping for the Inputs on an Accelaterm (CICP2800) 8/16 door controller?

Answer:
Note: An 8 door Accelaterm can have up to 3 I/O expansion boards connected to it.  A 16 door Accelaterm can only have 2 I/O expansion boards connected to it. Each I/O expansion board contains 16 additional inputs and 16 additional...