Answer:
The following details the generic control panel configuration settings required when installing an Elevator Recall system. Control panel features and programming may vary depending on applicable local codes and when integrated with other fire...
View Answer
Answer:
If you are unable to search for and find your iBridge IBR-ZREMOTE, iRemote-MOD or NL-MOD module(s) using the NL-MODCONFIG software (version 3.0.3.0 or later), perform the following:
...
View Answer
Answer:
CardAccess 3000 V2.3.16 and earlier - Supports up to 2 Access Groups per Badgeholder for panels and 6 for locks.
...
View Answer
Answer:
The Trilogy Networx Panel is a 1 Door (2 Reader) wireless controller. If both readers are used, they must be set up as IN/OUT readers (One on each side of the same door).
...
View Answer
Answer:
In PCD-Windows Quickloader software, open the User Assignment screen, User/Access Groups tab (shown below). For that Group program the AL (Alarm Level) for "1" and program the Code Type for "none".
View Answer
Answer:
The Gemini GEM-P3200, GEM-P9600 and GEM-X255 control panels running firmware version V70 and above have a prom chip that can be flashed for firmware upgrades (instead of a chip change). The existing control panel version can be verified by...
View Answer
Answer:
In PCD-Windows Quickloader, check the User Assignment screen, User Report Open/Close tab. Ensure Keyswitch Arming is checked to report openings and/or closings.
...
View Answer
Answer:
In PCD-Windows Quickloader, check the User Assignment screen, User Report Open/Close tab. Ensure EZ Arm is checked to report openings and/or closings.
...
View Answer
Answer:
In PCD-Windows Quickloader, check the User Assignment screen, User Report Open/Close tab. Ensure Auto Arm/Disarm is checked to report openings and/or closings.
...
View Answer
Answer:
In PCD-Windows Quickloader software, open the User Assignment screen, User/Access Groups tab (shown below). For that Group program the AL (Alarm Level) for "2" and program the Code Type for "none".
View Answer
Answer:
The input number for the tamper switch is input # 81. This must be configured under Configuration>Inputs to monitor the tamper switch.
View Answer
Answer:
Under System>System Settings, there is a setting called "Use Host For Global Midnight". This must be checked.
...
View Answer
Answer:
Refer to the following document:
http://tech.napcosecurity.com/index.php/techlibrary/downloadfile/id/272/embed/iframe
View Answer
Answer:
Configuring a lock down in the CardAccess 3000 software is done using the following features:
...
View Answer
Answer:
If there is too much power being drawn on the +12volts or +5volts, the Continental Controller will beep. If this occurs, remove the keypad or reader immediately.
View Answer
Answer:
The username(s) must be set up on the Salient Client that match the username(s) on the Salient Server.
View Answer
Answer:
Inputs on a 4 Door Turbo Superterm and a 4 Door Superterm map identical to a Smarterm. Using the wrong input numbers is a very common error that users make. For instance, the auxialary inputs on the top left of the board are...
View Answer
Answer:
Below is the link to the Virtual Inputs document:
http://tech.napcosecurity.com/index.php/techlibrary/downloadfile/id/1285/embed/iframe
View Answer
Answer:
Yes, but be aware that replaceable battery pack part number "9ETBATCASE" is designed to fit newer models, and thus may not fit inside older lock housings. Therefore, the non-replaceable battery pack can be used, (part number S6065).
View Answer
Answer:
A "deadbolt position monitor", shown in the image below, monitors the position of the deadbolt, i.e. either extended or retracted. Its general purpose, when the lock is programmed correctly, is to place the lock into or out of Residency Mode or...
View Answer
Answer:
For outside access using a rim cylinder and Finger Pull with the Model 250 / 260 / 700 / 710 exit locks, you may notice the door will not open easily if forced. This is intentional due to the "dead latch" design feature of these units....
View Answer
Answer:
Turn on a blow dryer to its highest "heat" setting and hold 12 inches from the top side inlets of the FWC-FSLC-HEAT detector. Maintain the hot air flow into the inlets until the lights turn red and unit goes into alarm. Turn off the...
View Answer
Answer:
For control panels GEM-P816, GEM-P1632 and GEM-P1664 firmware version 30 or higher, any keypad in the system can be used for keypad programming. For older control panel versions below V30, the programming keypad must be designated as "keypad...
View Answer
Answer:
Disconnect the yellow and green wires from the keypad. Wait for the keypad to display "Out of System", thus indicating the system has entered Keypad Configuration Mode.
View Answer
Answer:
The part number of the DL5300 Remote Release wires is 9CN238DBLSIDED.
View Answer
Answer:
The deadbolt is not intended to prevent entry by locking out a valid and enabled User Code entered at the keypad. All valid and enabled User Codes will provide entry regardless of the position of the deadbolt. The deadbolt is provided to...
View Answer
Answer:
Ensure the magnetic lock (maglock) is powered by disconnecting the momentary button wires and connecting them together. If the magnetic lock releases the door, the momentary release button likely needs to be replaced.
...
View Answer
Answer:
The DL-Windows software will always correctly maintain all data entered. When a User is added to a lock, the User No. assigned in the Lock Data screen depends on the next available "slot" (User No.) in the lock.
...
View Answer
Answer:
The "Double Tap" feature works identical for Wireless Locks with Prox readers and Continental Controllers with the latest firmware as of V2.11.84 and all versions of the CA4K software. For this function to work, you must select "Double read holds...
View Answer
Answer:
There are a few different import utilities available in the CardAccess 3000. They are listed below with a brief description:
...
View Answer
Answer:
Refer to the Continental Controller Service Manuals.
...
View Answer
Answer:
On some panels, a charged battery will not power up a panel that was not previously connected to AC. It requires the panel be connected to AC and then lose the AC. At that point, the battery will kick in immediately.
View Answer
Answer:
Yes, but the feature must be turned on in the software license/security key. This is unlike the other controllers.
View Answer
Answer:
The DL1200ET, DL1300ET and PDL1300ET will work with the Arrow S1200/1250, DCI 1200/1300, Von Duprin 22, Corbin ED8200 and the DORMA 5300 panic bar. Also works with the Von Duprin 33 series, but with the model 33A only right hand reverse (RHR)...
View Answer
Answer:
The part number for the DL2700 Lock Body assembly is S6045.
...
View Answer
Answer:
The length of the mortise cylinder in the DL3500 is 1-3/8".
View Answer
Answer:
Yes. When using the keypad to delete the User Code, be sure to use the number assigned to the user in the Lock Data screen. As shown in the example image below, use the number in the "User No" column (for example, the "12" circled in red). Do not use...
View Answer
Answer:
The Burglary bus wiring and Fire bus wiring can share the same conduit without adverse effects. Crosstalk (electromagnetic interference from an adjacent wire) is not an issue, as only one bus is polled at a time.
...
View Answer
40 Results Per Page | Showing
1161-1200 of 1901 Results
|
1
|
2
|
3
|
4
|
5
|
6
|
7
|
8
|
9
|
10
|
11
|
12
|
13
|
14
|
15
|
16
|
17
|
18
|
19
|
20
|
21
|
22
|
23
|
24
|
25
|
26
|
27
|
28
|
29
| 30 |
31
|
32
|
33
|
34
|
35
|
36
|
37
|
38
|
39
|
40
|
41
|
42
|
43
|
44
|
45
|
46
|
47
|
48