Answer:
The hasp driver on the V2.9.88 and V2.11.x DVDs, are not compatible with Windows 8.1 Pro and Server 2012 R2 and might fail. If a failure occurs, you must load it from a command prompt after the installation is complete. This is also noted...
View Answer
Answer:
The MA3000 Fire Alarm Control Panel was designed to perform an automatic low battery / no battery test every 4 hours, as per the requirement of UL 864 8th edition, the UL requirement in effect when the MA3000 control panel was manufactured. ...
View Answer
Answer:
If using the SLE Alarm Communicator as a primary communicator, 8 wires are required. If using the SLE Alarm Communicator as a backup, 10 wires are required. The recommended minimum (thinnest) wire gauge is 22AWG. We recommend...
View Answer
Answer:
When either Entry Zone door is opened, the system will begin the countdown programmed for that Entry Zone normally; if during this countdown the other Entry Zone door is opened, the system will immediately restart the countdown to reflect the full...
View Answer
Answer:
For single door installations, the backset is 2-3/4" measured from the edge of the door to the center of the 1-1/4" rim cylinder hole as indicated on the installation template (P5026) supplied with the unit.
...
View Answer
Answer:
With DL-Windows Software Version 5.1.1, select the User in the Global Users screen and type a unique PIN number for the User, then immediately erase this PIN number leaving the PIN field blank again. When you once more right-click this User to...
View Answer
Answer:
Yes! The iBridge IBR-ZREMOTE may be used to locally and remotely upload and download control panels through the internet. In addition, port forwarding of the local router port is NOT required.
...
View Answer
Answer:
Yes, the iREMOTE-MOD is compatible with the Gemini C-Series (GEMC) control panel, but with the Burglary area only. A GEMC-BK1 Burglary keypad skin is available for use on the www.MyRemoteKeypad.com website and for the iRemote App.
...
View Answer
Answer:
Control panel features and programming may vary depending on applicable local codes and when integrated with other fire protection systems (such as a sprinkler system). Consult with your AHJ for all local code requirements.
...
View Answer
Answer:
The first and quickest thing is to Swap Data 0 and Data 1 lines right at the panel. After doing so, swipe the badge and see if this corrects the problem. If not, put the Data lines back to their original position.
View Answer
Answer:
If a Barcode has a border or logo close to it, the ink from the border or logo might bleed off to the barcode and cause intermittan reads. Completely remove any borders or logos near the barcode and verify if the barcode reads...
View Answer
Answer:
To program a Marks IQ lockset in "terminator off" mode, first press the # key, then the GGM user ID number, followed by the GGM PIN number, followed by the standard programming steps for any given programming function as detailed in the programming...
View Answer
Answer:
If you are unable to add users with a PIN into your Marks IQ-Prox lock, it is likely the GGM is programmed with a proximity card instead of a PIN. When you are changing your GGM for the first time, specifying a proximity card (in the "PIN"...
View Answer
Answer:
The GEM-P3200, GEM-P9600 and GEM-X255 control panels (firmware version 60 and earlier) allow for a new EPROM chip to provide a new Master Security Code. Each GEM-P3200, GEM-P9600 and GEM-X255 control panel PC board contains a replaceable EPROM...
View Answer
Answer:
Open the Account listings screen that displays a list of your accounts, right-click the account you wish to change and click Edit.
...
View Answer
Answer:
You must call into Continental Sales for a phone activation.
...
View Answer
Answer:
The Alarm Lock NETDK's and NETPDK's are not supported on the Continental version of the Networx Panel. You must use a HID Prox/Keypad.
View Answer
Answer:
The EPI Canon Plug-In can be downloaded from the EPI (Imageware Systems) website at the following link:
https://iwsinc.com/about/support/epi_builder/
View Answer
Answer:
The following details the generic control panel configuration settings required when installing an Elevator Recall system. Control panel features and programming may vary depending on applicable local codes and when integrated with other fire...
View Answer
Answer:
If you are unable to search for and find your iBridge IBR-ZREMOTE, iRemote-MOD or NL-MOD module(s) using the NL-MODCONFIG software (version 3.0.3.0 or later), perform the following:
...
View Answer
Answer:
CardAccess 3000 V2.3.16 and earlier - Supports up to 2 Access Groups per Badgeholder for panels and 6 for locks.
...
View Answer
Answer:
The Trilogy Networx Panel is a 1 Door (2 Reader) wireless controller. If both readers are used, they must be set up as IN/OUT readers (One on each side of the same door).
...
View Answer
Answer:
In PCD-Windows Quickloader software, open the User Assignment screen, User/Access Groups tab (shown below). For that Group program the AL (Alarm Level) for "1" and program the Code Type for "none".
View Answer
Answer:
The Gemini GEM-P3200, GEM-P9600 and GEM-X255 control panels running firmware version V70 and above have a prom chip that can be flashed for firmware upgrades (instead of a chip change). The existing control panel version can be verified by...
View Answer
Answer:
In PCD-Windows Quickloader, check the User Assignment screen, User Report Open/Close tab. Ensure Keyswitch Arming is checked to report openings and/or closings.
...
View Answer
Answer:
In PCD-Windows Quickloader, check the User Assignment screen, User Report Open/Close tab. Ensure EZ Arm is checked to report openings and/or closings.
...
View Answer
Answer:
In PCD-Windows Quickloader, check the User Assignment screen, User Report Open/Close tab. Ensure Auto Arm/Disarm is checked to report openings and/or closings.
...
View Answer
Answer:
In PCD-Windows Quickloader software, open the User Assignment screen, User/Access Groups tab (shown below). For that Group program the AL (Alarm Level) for "2" and program the Code Type for "none".
View Answer
Answer:
The input number for the tamper switch is input # 81. This must be configured under Configuration>Inputs to monitor the tamper switch.
View Answer
Answer:
Under System>System Settings, there is a setting called "Use Host For Global Midnight". This must be checked.
...
View Answer
Answer:
Refer to the following document:
http://tech.napcosecurity.com/index.php/techlibrary/downloadfile/id/272/embed/iframe
View Answer
Answer:
Configuring a lock down in the CardAccess 3000 software is done using the following features:
...
View Answer
Answer:
If there is too much power being drawn on the +12volts or +5volts, the Continental Controller will beep. If this occurs, remove the keypad or reader immediately.
View Answer
Answer:
The username(s) must be set up on the Salient Client that match the username(s) on the Salient Server.
View Answer
Answer:
Inputs on a 4 Door Turbo Superterm and a 4 Door Superterm map identical to a Smarterm. Using the wrong input numbers is a very common error that users make. For instance, the auxialary inputs on the top left of the board are...
View Answer
Answer:
Below is the link to the Virtual Inputs document:
http://tech.napcosecurity.com/index.php/techlibrary/downloadfile/id/1285/embed/iframe
View Answer
Answer:
Yes, but be aware that replaceable battery pack part number "9ETBATCASE" is designed to fit newer models, and thus may not fit inside older lock housings. Therefore, the non-replaceable battery pack can be used, (part number S6065).
View Answer
Answer:
A "deadbolt position monitor", shown in the image below, monitors the position of the deadbolt, i.e. either extended or retracted. Its general purpose, when the lock is programmed correctly, is to place the lock into or out of Residency Mode or...
View Answer
40 Results Per Page | Showing
1161-1200 of 1921 Results
|
1
|
2
|
3
|
4
|
5
|
6
|
7
|
8
|
9
|
10
|
11
|
12
|
13
|
14
|
15
|
16
|
17
|
18
|
19
|
20
|
21
|
22
|
23
|
24
|
25
|
26
|
27
|
28
|
29
| 30 |
31
|
32
|
33
|
34
|
35
|
36
|
37
|
38
|
39
|
40
|
41
|
42
|
43
|
44
|
45
|
46
|
47
|
48
|
49