Results Per Page | Showing 1-45 of 45 Results
| 1
Date Added: 5/1/07
Details regarding Gemini Control Panel GEM-P1632 firmware V30B; the new address locations and new features.
Posted in [Tech Notes]
Tags:
GEM-P1632
Date Added: 1/6/11
Tech Note: Zones programmed for AutoBypass Re-Entry do not re-enter the system when secured (GEM-P816, GEM-P1632, GEM-P1664 (V30J or prior).
Posted in [Tech Notes]
Tags:
GEM-P1664
GEM-P1632
GEM-P816
Date Added: 3/3/16
TROUBLE CODES AND CONDITIONS
Listed below are the trouble codes and conditions for the Gemini GEM-P816, GEM-P1632, GEM-P3200, GEM-P9600, GEM-X255 and GEMC "C-Series" control panels.
NN = Device of zone number. Note: "E" messages not listed here are currently undefined and reserved for future use.
E01-00 – A/C POWER FAILURE
E02-00 – SYSTEM LOW BATTERY
E03-00 – COMMUNICATIONS FAILURE OVER A PHONE LINE
E04-NN – RF TRANSMITTER SUPERVISORY FAILURE
E05-NN – RF TRANSMITTER LOW BATTERY
E06-NN – RF RECEIVER RESPONSE TROUBLE
E07-00 – DOWNLOAD ATTEMPT FAILURE
E08-00 – TELCO LINE 1 FAILURE
E09-00 – SYSTEM COLD START (NO PANEL PROGRAM)
E10-NN – BURGLARY KEYPAD RESPONSE TROUBLE
E11-NN – BURGLARY KEYPAD/ ACM TAMPER
E12-NN – BURGLARY EZM RESPONSE TROUBLE
E13-NN – BURGLARY EZM TAMPER
E14-NN – RELAY BOARD RESPONSE TROUBLE
E15-NN – RF TRANSMITTER TAMPER
E16-NN – RF RECEIVER JAMMED
E17-NN – RF RECEIVER TAMPER
E18-NN – WIRELESS KEYFOB LOW BATTERY
E19-00 – USER PROGRAM MEMORY ERROR
E20-00 – DEALER PROGRAM MEMORY ERROR
E21-00 – SYSTEM SHUT DOWN
E22-NN – SENSOR WATCH ACTIVITY FAILURE
E23-00 – BURGLARY BUS FAILURE
E24-00 – SERVICE MESSAGE
E25-00 – COMMUNICATIONS FAILURE OVER INTERNET TCP/IP
E26-00 – SYSTEM GROUND FAULT
E27-00 – PRINTER FAILURE
E28-00 – FIRE BUS FAILURE
E29-00 – FIRE FBS BOARD TROUBLE
E30-NN – FIRE EZM AUX POWER FAILURE
E31-NN – FIRE EZM RESPONSE TROUBLE
E32-NN – FIRE KEYPAD RESPONSE TROUBLE
E33-NN – FIRE EZM TAMPER
E34-NN – FIRE KEYPAD TAMPER
E35-NN – SUPERVISORY RELAY TROUBLE
E36-NN – FIRE EZM GROUND FAULT
E37-NN – FIRE EZM A/C FAILURE
E38-NN – FIRE EZM LOW BATTERY
E39-00 – RF RECEIVER CAPACITY ERROR
E40-NN – RF DUAL TEC SELF TEST FAILURE
E41-00 – SYSTEM FIRE TROUBLE
E42-NN- CO ZONE TROUBLE
E51-00 – ALARM SUPERVISORY FAILURE
E54-00 – LOW BATTERY/AC FAIL FOR ACM #1
E55-00 – LOW BATTERY/AC FAIL FOR ACM #2
E56-00 – LOW BATTERY/AC FAIL FOR ACM #3
E57-00 – LOW BATTERY/AC FAIL FOR ACM #4
E58-00 – TELEMETRY TROUBLE
E59-00 – TELEMETRY FAILURE BETWEEN NL-MOD & PANEL
E66-00 – CLEAN ME SMOKE DETECTOR DIRTY
E99-00 – KEYPAD PANIC WIRE TROUBLE
Posted in [Miscellaneous]
Tags:
GEMC
GEM-X255
GEM-P9600
GEM-P3200
GEM-P1632
GEM-P816
Date Added: 9/12/18
How to program a "Test Timer" automatic test report (GEM-P1632 Control Panel).
Posted in [Video Tech Tips]
Tags:
GEM-P1632
Date Added: 1/10/19
How to control access through a special door (e.g. garage door, pool gate, storage room, etc.) using a keypad.
Posted in [Video Tech Tips]
Tags:
GEM-P1632
GEM-P9600
Date Added: 3/25/16
Wiring Diagram detailing the integrated wiring connections using the Gemini GEM-P1632 control panel, the SLE-GSM Communicator, the SLE-DLEXT Extender Module and the SLE-SMTCHG Smart Charge Module.
Posted in [Tech Tips]
Tags:
SLe-SMTCHG
SLe-DLEXT
SLe-GSM
GEM-P1632
Date Added: 6/18/20
Upgrading a GEM-P816 and GEM-P1632 V10D for iBridge Compatibility.
If you wish to use the iBridge IBR-ZREMOTE module, other iBridge system components or a StarLink Connect Communicator with an older GEM-P816 or GEM-P1632 control panel running firmware version 10D, this older control panel firmware must be upgraded to V31BA (or higher).
Posted in [Tech Notes]
Tags:
IBR-ZREMOTE
iBridge
GEM-P1632
GEM-P816
StarLink Connect
StarLink
Date Added: 10/20/20
Download one WinZip file containing instructions and files for updating:
--GEM-X255, GEM-P9600 and GEM-P3200 control panel firmware;
--The NAPCO Control4 driver that functions with the NAPCO GEM-X255, GEM-P9600 and GEM-P3200 control panels and the NAPCO GEM-P816, GEM-P1632 and GEM-P1664 control panels with an IBR-ZREMOTE installed;
--The IBR-ZREMOTE firmware (both for the new IBR-ZREMOTE with a single Ethernet socket and for the legacy IBR-ZREMOTE with two Ethernet sockets);
--The NL-MODCONFIG software program.
Posted in [Software / Firmware]
Tags:
NL-MODCONFIG
IBR-ZREMOTE
GEM-P1664
GEM-P1632
GEM-P816
Control4
GEM-P3200
GEM-P9600
GEM-X255
Date Added: 1/11/24
GEM-P1632 Control Panel/Communicator Installation Instructions (Version 31G). Conforms to UL 985.
Posted in [Installation Manuals]
Tags:
GEM-P1632
Date Added: 4/4/24
Tech Tip: Zone ANDing: Gemini Control Panels GEM-P816, GEM-P1632, and GEM-P1664.
With the GEM-P816, GEM-P1632, and GEM-P1664, up to 4 groups of two (or more) zones each can be "AND"ed whereby the system to go into alarm only if any two zones of the group are tripped within 2 minutes. The Zone ANDing feature is designed to afford redundant protection for certain devices, such as glass break detectors, PIRs, etc., that may show a tendency to false under certain conditions. For more information, see this Tech Tip.
Posted in [Tech Tips]
Tags:
GEM-P816
GEM-P1632
GEM-P1664
Date Added: 2/10/17
Enable "Panel Access" to Energize an external relay connected to PGM2 ("Programmable Output 2").
Models: Gemini GEM-P816, GEM-P1632 & GEM-P1664 Control Panels.
Posted in [Tech Tips]
Tags:
GEM-P1632
GEM-P1664
GEM-P816
Date Added: 4/19/13
How use Quickloader to configure Primary Reporting via NetLink and Backup Reporting via StarLink Communicators with no landline.
Models: GEM-P816 and GEM-P1632 Control Panels (version 30M or greater) GEM-P3200, GEM-P9600 and GEM-X255 Control Panels (version 50 or greater) NL-MOD Network Communication Module NL-RCM Remote Control Module SLe-GSM and SL-1FD-T StarLink Communicators
Posted in [Tech Tips]
Tags:
GEM-P1632
GEM-P3200
GEM-P816
GEM-P9600
GEM-X255
NL-MOD
NL-RCM
PCD-Windows
Quickloader
SL-1FD-T
SLe-GSM
Date Added: 7/11/24
Models: GEMINI GEM-P1632, GEM-P1632-Version2, GEM-P1632-Version 3, *GEMP1664, GEM-P816, GEM-P816-Version 2 and GEM-P816-Version 3 combination fire and burglary alarm control units.
Posted in [CSFM Listings]
Tags:
GEM-P1632
GEM-P1664
GEM-P816
Date Added: 9/6/24
Keyfob Event History Mapping with Gemini Control Panels: GEM-P816, GEM-P1632, GEM-P1664, GEM-P3200, GEM-P9600, GEM-X255.
The keyfob OP/CL log displays most the recent event history of openings and closings. This log uses the last group of users depending on the control panel and the number of available users. For examples, see this Tech Tip.
Posted in [Tech Tips]
Tags:
GEM-KEYF
GEM-P1632
GEM-P1664
GEM-P3200
GEM-P816
GEM-P9600
GEM-X255