Results Per Page | Showing 1-9 of 9 Results
| 1
Date Added: 7/10/14
Securing an unlocked Trilogy lockset with a drained battery pack.
Applies to models DL/PDL3500, DL/PDL4500, DL/PDL6500, ETDL, ETDLN, ETPDL, ETPDLN, ETPLN, ETPDLNRX, ETPLNRX, PDL6600.
Posted in [Tech Tips]
Tags:
PDL6600
ETPDLNRX
ETPLNRX
ETPLN
ETPDLN
ETPDL
ETDLN
ETDL
PDL6500
DL6500
PDL4500
DL4500
PDL3500
DL3500
Date Added: 4/2/13
(This firmware is a beta version for Continental Instruments).
File name: PDL6600_68d.bin
Networx PDL6600 Firmware- 68d.
Important: After updating the firmware, you MUST perform a FULL download to the lock (i.e. Users, Features, Schedules and Time/Date). Then use a valid code or card to ensure access is granted with its valid "access granted" beeps and LED lights. However, if following the valid "access granted" indication you then hear 1 long beep and 5 short beeps, the lock must then be defaulted, re-discovered and the lock profile re-downloaded. Rest assured that your Gateway always maintains your lock information. Therefore, after defaulting the lock simply re-discover the lock and DL-Windows will manage the "re-configuration process".
Note: The firmware version letter type case ("upper case" or "lower case") displayed in the file name may differ and from the case displayed in DL-Windows. Be aware that both letters always denote the same version.
Posted in [Software / Firmware]
Tags:
PDL6600
Networx
Date Added: 10/11/17
Supports Version 2 Gateways and Expanders and the Emergency Indicator Lightbar on the inside ("protected" side) of the door.
Also includes other updated keypad programming features.
File name: PDL6600_68j.bin
Networx PDL6600 Firmware- 68j.
Important: After updating the firmware, you MUST perform a FULL download to the lock (i.e. Users, Features, Schedules and Time/Date). Then use a valid code or card to ensure access is granted with its valid "access granted" beeps and LED lights. However, if following the valid "access granted" indication you then hear 1 long beep and 5 short beeps, the lock must then be defaulted, re-discovered and the lock profile re-downloaded. Rest assured that your Gateway always maintains your lock information. Therefore, after defaulting the lock simply re-discover the lock and DL-Windows will manage the "re-configuration process".
Note: The firmware version letter type case ("upper case" or "lower case") displayed in the file name may differ and from the case displayed in DL-Windows. Be aware that both letters always denote the same version.
FIRMWARE UPDATE 68j INCLUDES THE FOLLOWING NEW FEATURES:
- Supports Lockdown Sounder on Emergency
- Supports Lockdown Lightbar Indicator on Emergency
- Lock responds to GLOBAL Emergency Lockdown commands
- Lock responds to LOCAL Emergency Lockdown commands
- Faster communication "Wake up" time when using version 2 Gateways
- Manually unlock door using DL-Windows software (v5.5.3)
Support added for the following keypad programming options:
(AL) 8 Exit Program Mode
(AL) 67 (AL) 43 Enable Sounder on Emergency
(AL) 67 (AL) 44 Enable Inside Emergency Indicator
(AL) 67 (AL) 45 Activate Local Emergency (by keypad)
(AL) 67 (AL) 46 Activate Global Emergency (by keypad)
(AL) 67 (AL) 47 Activate Local Emergency (by keyfob; requires RR-4BKEYFOB)
(AL) 67 (AL) 48 Activate Global Emergency (by keyfob; requires RR-4BKEYFOB)
Posted in [Software / Firmware]
Tags:
Networx
PDL6600
Date Added: 1/25/23
Wireless Trilogy PDL6600 & ETPDLNRX with Door Monitoring Programming Instructions.
Includes new keypad programming option, "Prox Enroll Time Bypass".
Posted in [Programming Manuals]
Tags:
ETPDLNRX
PDL6600
Date Added: 3/20/13
DL6600 and PDL6600 Mortise Installation Template (with "Door Monitoring", WI2036). The DL6600 and PDL6600 series Mortise locks have a "Door Monitoring" feature that necessitates a "door contact" hole be drilled. Therefore, the "door contact" hole was added to the standard Mortise Installation Template (WI1003) to make this template WI2036. Use this Mortise template WI2036 with the Mortise installation instructions and its supplement (WI2023) describing the steps required to install the "door contact" hole.
IMPORTANT! WHEN PRINTING OR PHOTOCOPYING A TEMPLATE, ALWAYS SELECT PRINTING OPTIONS TO ENSURE THAT COPIES ARE PRINTED WITHOUT SIZE ADJUSTMENTS. ALWAYS VERIFY DIMENSIONS ON THE TEMPLATE AFTER PRINTING.
Posted in [Templates]
Tags:
DL6600
Mortise
PDL6600
Date Added: 7/22/24
This Exit Trim documentation package (WI2750LF) contains the following documents:
(WI1133) -- Addendum for Proper Start-Up
(WI1163) -- Cylinder Adapter Kits
(WI1177) -- Cylinder Adapter Kit - Align Gears
(WI1822) -- Dielectric Grease Notice
(WI1880) -- Networx Relay Colors
(WI1994) -- Addm Spindle Spacer Lever
(WI2027) -- Programming Instructions
(WI2109) -- Request to Exit Orange Wire Description
(WI2110) -- Door Contact Sensor / Magnet Install Instructions
(WI2206) -- Emergency Light Bar
(WI2229) -- Firmware Upgrade Notice
(WI2061A) -- After Lock Installation on Door (Latest version)
Posted in [Installation Manuals]
Tags:
ETPDLNRX
Exit Trim
PDL6600
Date Added: 7/23/24
This Exit Trim 'Request to Exit" Documentation Package for the PDL6600 & ETPDLNRX (WI2775LF) contains the following documents:
(WI1133) -- Addendum for Proper Start-Up
(WI1163) -- Cylinder Adapter Kits
(WI1177) -- Cylinder Adapter Kit - Supplement
(WI1822) -- Dielectric Grease Notice
(WI1880) -- Networx Relay Colors
(WI2027) -- Programming Instructions PDL6600 / ETPDLNRX
(WI2109) -- RX Orange Wire Notice
(WI2110) -- Door Contact Instructions
(WI2206) -- Emergency Light Bar
(WI2229) -- Firmware Notice
(WI2061A) -- After Lock Installation on Door (Latest version)
Posted in [Installation Manuals]
Tags:
ETPDLNRX
PDL6600
Date Added: 7/23/24
This PDL6600 & ETPDLNRX Documentation Package (WI2765LF) contains the following documents:
(WI1133) Addendum for Proper Start-Up
(WI1163) Cylinder Adapter Kits
(WI1177) Cylinder Adapter Kit Addendum
(WI1822) Dielectric Grease Notice
(WI1880) Networx Relay Colors
(WI2027) Programming Instructions PDL6600 ETPDLNRX
(WI2109) RX Orange Wire Addendum
(WI2110) Door Contact Addendum
(WI2206) Emergency Light Bar Addendum
(WI2229) Firmware Addendum
(WI2061A) -- After Lock Installation on Door (Latest version)
Posted in [Installation Manuals]
Tags:
ETPDLNRX
PDL6600