Results Per Page | Showing 1-9 of 9 Results | 1

Lever and Return Spring Upgrade Kit

Date Added: 5/2/12

Lever and Return Spring Upgrade Kit. Applies to Exit Trim and Mortise Locks only.

Posted in [Installation Manuals]
Tags:

Modified Outside Housing Requires New Lever

Date Added: 7/18/12

Modified Outside Housing Requires New Lever A design modification to the outside housing requires a shorter outside Lever, as the existing Lever will not fit into the modified outside housing. A new Spindle Spacer must also be used. Note: Refer to these documents for additional information: WI2008 (Lever and Return Spring Upgrade Kit) and WI1994 (Exit Trim & Mortise Locks New Spindle Spacer & Lever).

Posted in [Tech Notes]
Tags:

Outside Housing Design Modification Requires Updated Lever

Date Added: 4/17/13

Outside Housing Design Modification Requires Updated Lever. An internal design upgrade has been implemented that affects the replacement of the outside housing of Alarm Lock mortise and Exit Trim locksets (NOT including narrow stile).

Posted in [Tech Notes]
Tags:

Trilogy Proximity Mortise Locks, PDL3500 Specification Sheet

Date Added: 1/7/02

Trilogy Proximity Mortise Locks, PDL3500 Specification Sheet.

Posted in [Sales/Marketing Spec. Sheets]
Tags:

DL6600, PDL6600 Mortise Installation Template (with "Door Monitoring", WI2036)

Date Added: 3/20/13

DL6600 and PDL6600 Mortise Installation Template (with "Door Monitoring", WI2036). The DL6600 and PDL6600 series Mortise locks have a "Door Monitoring" feature that necessitates a "door contact" hole be drilled. Therefore, the "door contact" hole was added to the standard Mortise Installation Template (WI1003) to make this template WI2036. Use this Mortise template WI2036 with the Mortise installation instructions (WI1004) and its supplement (WI2023) describing the steps required to install the "door contact" hole.

IMPORTANT!  WHEN PRINTING OR PHOTOCOPYING A TEMPLATE, ALWAYS SELECT PRINTING OPTIONS TO ENSURE THAT COPIES ARE PRINTED WITHOUT SIZE ADJUSTMENTS.  ALWAYS VERIFY DIMENSIONS ON THE TEMPLATE AFTER PRINTING.

Posted in [Templates]
Tags:

Supplemental Lubrication of Mortise Door Lock Models with Pivoting Dead Latch

Date Added: 11/1/18

Technical Service Bulletin

Supplemental Lubrication of Mortise Door Lock Models with Pivoting Dead Latch

Some mortise door locks equipped with pivoting dead latches may require additional internal lubrication to ensure optimal operation. The procedure described in this document should be performed for all new installations and existing locks in service.

Posted in [Miscellaneous]
Tags:

Supplemental Lubrication of Mortise Door Lock Models with Pivoting Dead Latch

Date Added: 11/1/18

Technical Service Bulletin

Supplemental Lubrication of Mortise Door Lock Models with Pivoting Dead Latch

Some mortise door locks equipped with pivoting dead latches may require additional internal lubrication to ensure optimal operation. The procedure described in this document should be performed for all new installations and existing locks in service.

Posted in [Miscellaneous]
Tags:

How to Reverse the Hand of the Latch on Alarm Lock Mortise Locks

Date Added: 7/25/19

How to Reverse the Hand of the Latch on Alarm Lock Mortise Locks.

These instructions apply to current mortise lock bodies, including models with a deadbolt.

Posted in [Tech Tips]
Tags:

DL6500, PDL6500 Mortise Installation Template (WI1003)

Date Added: 8/1/08

DL6500, PDL6500 Mortise Installation Template (WI1003).

Also see this vervy helpful supplement to the template:  ASA Strike Plate for All Alarm Lock Mortise Locks.

IMPORTANT!  WHEN PRINTING OR PHOTOCOPYING A TEMPLATE, ALWAYS SELECT PRINTING OPTIONS TO ENSURE THAT COPIES ARE PRINTED WITHOUT SIZE ADJUSTMENTS.  ALWAYS VERIFY DIMENSIONS ON THE TEMPLATE AFTER PRINTING.

Posted in [Templates]
Tags: