Results Per Page | Showing 1-7 of 7 Results
| 1
Date Added: 8/1/16
DL6200, PDL6200 and PDL8200 with Door Monitoring Installation Template.
IMPORTANT! WHEN PRINTING OR PHOTOCOPYING A TEMPLATE, ALWAYS SELECT PRINTING OPTIONS TO ENSURE THAT COPIES ARE PRINTED WITHOUT SIZE ADJUSTMENTS.
AFTER PRINTING, ALWAYS VERIFY THE DIMENSIONS ON THE TEMPLATE.
Posted in [Templates]
Tags:
PDL8200
PDL6200
DL6200
Date Added: 8/9/16
Wireless Trilogy PDL6200 and PDL8200 (with Door Monitoring and 13.56MHz Smart Card support with the PDL8200) Programming Instructions.
Posted in [Programming Manuals]
Tags:
PDL6200
PDL8200
Date Added: 8/8/16
(Beta version)
This firmware supports "Version 2" Gateways and Expanders!
File name: PDL6200_67k.bin
Networx PDL6200 Firmware- 67k.
Important: After updating the firmware, you MUST perform a FULL download to the lock (i.e. Users, Features, Schedules and Time/Date). Then use a valid code or card to ensure access is granted with its valid "access granted" beeps and LED lights. However, if following the valid "access granted" indication you then hear 1 long beep and 5 short beeps, the lock must then be defaulted, re-discovered and the lock profile re-downloaded. Rest assured that your Gateway always maintains your lock information. Therefore, after defaulting the lock simply re-discover the lock and DL-Windows will manage the "re-configuration process".
Note: The firmware version letter type case ("upper case" or "lower case") displayed in the file name may differ and from the case displayed in DL-Windows. Be aware that both letters always denote the same version.
Posted in [Software / Firmware]
Tags:
PDL6200
Networx
Date Added: 2/15/18
This firmware supports "Version 2" Gateways and Expanders!
File name: PDL6200_67L.bin
Networx PDL6200 Firmware- 67L.
Important: After updating the firmware, you MUST perform a FULL download to the lock (i.e. Users, Features, Schedules and Time/Date). Then use a valid code or card to ensure access is granted with its valid "access granted" beeps and LED lights. However, if following the valid "access granted" indication you then hear 1 long beep and 5 short beeps, the lock must then be defaulted, re-discovered and the lock profile re-downloaded. Rest assured that your Gateway always maintains your lock information. Therefore, after defaulting the lock simply re-discover the lock and DL-Windows will manage the "re-configuration process".
Note: The firmware version letter type case ("upper case" or "lower case") displayed in the file name may differ and from the case displayed in DL-Windows. Be aware that both letters always denote the same version.
FIRMWARE UPDATE 67L INCLUDES THE FOLLOWING NEW FEATURES:
- Supports Lockdown sounder on Emergency
- Supports Lockdown indicator lightbar on Emergency
- Lock responds to GLOBAL Emergency Lockdown commands
- Lock responds to LOCAL Emergency Lockdown commands
- Faster communication "Wake up" time when using version 2 Gateways
- Manually unlock door using DL-Windows software (v5.5.3)
Support added for the following keypad programming options:
(AL) 8 Exit Program Mode
(AL) 67 (AL) 43 Enable Sounder on Emergency
(AL) 67 (AL) 44 Enable Inside Emergency Indicator
(AL) 67 (AL) 45 Activate Local Emergency (by keypad)
(AL) 67 (AL) 46 Activate Global Emergency (by keypad)
(AL) 67 (AL) 47 Activate Local Emergency (by keyfob; requires RR-4BKEYFOB)
(AL) 67 (AL) 48 Activate Global Emergency (by keyfob; requires RR-4BKEYFOB)
Posted in [Software / Firmware]
Tags:
PDL6200
Date Added: 11/27/24
This PDL6200 Documentation Package (WI2736LF) includes the following documents:
WI1133: Proper Start-Up
WI1152: DL-Windows Quick Start
WI1822: Dielectric Grease
WI1871: How to Remove Inside Housing from Spindle
WI1880: Networx Relay Colors
WI2024: Installation Instructions
WI2203: Programming Instructions
WI2206: Emergency Light Bar
WI2229: Update Firmware Notification
(WI2061B) -- After Lock Installation on Door (Latest version)
Posted in [Installation Manuals]
Tags:
PDL6200