Results Per Page | Showing 1-10 of 10 Results | 1

StarLink MAX Communicators -- Submittal Data Sheets

Date Added: 5/20/22

StarLink MAX Communicators -- Submittal Data Sheets. 

WinZip file contains:

A816LF: StarLink™ SLE-MAXA and SLE-MAXV Residential / Commercial Series Sole Path Alarm Communicators

A817LF: StarLink™ SLE-MAXA-CB, SLE-MAXV-CB, SLE-MAXA-CB-TF and SLE-MAXV-CB-TF Commercial Series Alarm Communicators

A818LF: StarLink™ SLE-MAXVI-FIRE and SLE-MAXAI-FIRE Commercial Sole/Dual-Path Alarm Communicators

A819LF: StarLink™ SLE-MAXVI-CFB, SLE-MAXAI-CFB, SLE-MAXVI-CFBPS and SLE-MAXAI-CFBPS Commercial Sole/Dual-Path Alarm Communicators

Posted in [Data Sheets - AHJ Submittal]
Tags: SLE-MAXA SLE-MAXV SLE-MAXA-CB SLE-MAXV-CB SLE-MAXA-CB-TF SLE-MAXV-CB-TF SLE-MAXVI-FIRE SLE-MAXAI-FIRE SLE-MAXVI-CFB SLE-MAXAI-CFB SLE-MAXVI-CFBPS SLE-MAXAI-CFBPS

NAPCO StarLink Commercial Fire Communicator: SLE-MAXVI-FIRE, SLE-MAXAI-FIRE, SLE-MAXVI-CFB, SLE-MAXAI-CFB Dial Capture Wiring Diagram

Date Added: 8/14/23

NAPCO StarLink Commercial Fire Communicator
SLE-MAXVI-FIRE & SLE-MAXAI-FIRE (Dual Path - Plastic Enclosure)
SLE-MAXVI-CFB & SLE-MAXAI-CFB (Dual Path - Metal Enclosure)
Dial Capture Wiring Diagram

(WinZip file contains both .dwg and .pdf file formats)

Posted in [CAD Drawings]
Tags: SLE-MAXAI-CFB SLE-MAXVI-CFB SLE-MAXAI-FIRE SLE-MAXVI-FIRE

NAPCO StarLink Commercial Fire Communicator: SLE-MAXVI-FIRE, SLE-MAXAI-FIRE, SLE-MAXVI-CFB, SLE-MAXAI-CFB Input Wiring Diagram

Date Added: 8/14/23

NAPCO StarLink Commercial Fire Communicator
SLE-MAXVI-FIRE & SLE-MAXAI-FIRE (Dual Path - Plastic Enclosure)
SLE-MAXVI-CFB & SLE-MAXAI-CFB (Dual Path - Metal Enclosure)
Input Wiring Diagram

(WinZip file contains both .dwg and .pdf file formats)

Posted in [CAD Drawings]
Tags: SLE-MAXAI-CFB SLE-MAXVI-CFB SLE-MAXAI-FIRE SLE-MAXVI-FIRE

New York City Certificate of Approval (SLE-MAX Series Dual Path Communicators)

Date Added: 1/25/24

New York City Certificate of Approval for SLE-MAX Series Dual Path Communicator models:  SLE-MAXAI-FIRE, SLE-MAXAI-CFBPS, SLE-MAXAI-CFB, SLE-MAXVI-FIRE, SLE-MAXVI-CFBPS, SLE-MAXVI-CFB, SLE-MAX2-FIRE, SLE-MAX2-CFBPS, and SLE-MAX2-CFB.

(Fire Alarm Equipment Accessory) - SLE-FIRE-VR.

Pertinent Code Section(s): Section FC 901 of the New York City Fire Code

Prescribed Tests: UL 864 10th Edition, NFPA 72

Laboratories: Underwriters Laboratories, Inc. (UL)

Report(s): UL Certification Certificate Number S2576 Report Reference S2576 -20150410, Date 2023-March-24

ETL Certification Number 104519361NYM-001 dated Oct. 3, 2023.

Posted in [NYC Certificates of Approval]
Tags: SLE-MAX2-CFB SLE-MAX2-CFBPS SLE-MAX2-FIRE SLE-MAXVI-CFB SLE-MAXVI-CFBPS SLE-MAXVI-FIRE SLE-MAXAI-CFB SLE-MAXAI-CFBPS SLE-MAXAI-FIRE

StarLink SLE-MAXAI-FIRE Instructions d'installation

Date Added: 7/1/23

StarLink Instructions d'installation pour le modèle :

StarLink Installation Instructions for Model:

SLE-MAXAI-FIRE

Posted in [Installation Manuals]
Tags: SLE-MAXAI-FIRE

Firmware for the StarLink MAXAI / MAXVI Dual Path Communicators (226.0.92 / 31.1)

Date Added: 5/31/24

Firmware for the StarLink MAXAI / MAXVI Dual Path Communicators (226.0.92 / 31.1)

For models:  SLE-MAXAI-FIRE, SLE-MAXAI-CFB, SLE-MAXAI-CFBPS, SLE-MAXVI-FIRE, SLE-MAXVI-CFB, and SLE-MAXVI-CFBPS.

Posted in [Software / Firmware]
Tags: SLE-MAXAI-CFB SLE-MAXAI-CFBPS SLE-MAXAI-FIRE SLE-MAXVI-CFB SLE-MAXVI-CFBPS SLE-MAXVI-FIRE

BOSCH / RADIONICS MODEM II & MODEM III Reporting Formats

Date Added: 3/12/24

The Bosch/Radionics Modem II and Modem III re-porting formats are dial captured from the alarm control panel in the same manner as CID and 4/2 formats.

These formats have been evaluated by ETL/Intertek in the following models:

SLE-LTEVI-CFBPS, SLE-LTEVI-CFB, SLE-LTEAI-CFBPS, SLE-LTEAI-CFB, SLE-FNI-FIRE, SLE-FNI-CFB, SLE-FNI-CFB-PS, SLE-LTEVI-FIRE, SLE-LTEAI-FIRE, SLE-LTBVI-FIRE, SLE-LTBVI-CFB, SLE-LTBVI-CFBPS, SLE-MAXVI-CFBPS, SLE-MAXVI-CFB, SLE-MAXAI-CFBPS, SLE-MAXAI-CFB, SLE-MAXVI-FIRE, SLE-MAXAI-FIRE, SLE-MAX2-FIRE, SLE-MAX2-CFB and SLE-MAX2-CFBPS.

------------------------------------------------

Click here for StarLink Radio Programming Video Tech Tips

Posted in [Installation Manuals]
Tags: SLE-FNI-CFB SLE-FNI-CFB-PS SLE-FNI-FIRE SLE-LTBAI-CFB SLE-LTBAI-CFBPS SLE-LTBAI-FIRE SLE-LTBVI-CFB SLE-LTBVI-CFBPS SLE-LTBVI-FIRE SLE-LTEAI-CFB SLE-LTEAI-CFBPS SLE-LTEAI-FIRE SLE-LTEVI-CFB SLE-LTEVI-CFBPS SLE-LTEVI-FIRE SLE-MAX2-CFB SLE-MAX2-CFBPS SLE-MAX2-FIRE SLE-MAXAI-CFB SLE-MAXAI-CFBPS SLE-MAXAI-FIRE SLE-MAXVI-CFB SLE-MAXVI-CFBPS SLE-MAXVI-FIRE SLE-MF-JMP

Documentation Package for the StarLink Commercial SLE-MAXVI-FIRE & SLE-MAXAI-FIRE Sole/Dual-Path Alarm Communicators

Date Added: 7/7/23

This documentation package (WI2577.aLF) for the StarLink Commercial SLE-MAXVI-FIRE & SLE-MAXAI-FIRE Sole/Dual-Path Alarm Communicators contains the following documents in one PDF file:

• SLE-MAXVI-FIRE & SLE-MAXAI-FIRE Installation Instructions (WI2465.bLF)
• ComNet Activation Instructions (WI2114C)

This documentation package is part number WI2577.aLF.

------------------------------------------------

Click here for StarLink Radio Programming Video Tech Tips

Click here for StarLink MAX Communicator Submittal Data Sheets

Posted in [Installation Manuals]
Tags: SLE-MAXAI-FIRE SLE-MAXVI-FIRE StarLink

StarLink Commercial SLE-MAXVI-FIRE & SLE-MAXAI-FIRE Sole/Dual-Path Alarm Communicators: Installation Instructions

Date Added: 7/6/23

StarLink Commercial SLE-MAXVI-FIRE & SLE-MAXAI-FIRE Sole/Dual-Path Alarm Communicators:  Installation Instructions.

Click here for StarLink MAX Communicator Submittal Data Sheets.

------------------------------------------------

Click here for StarLink Radio Programming Video Tech Tips

Posted in [Installation Manuals]
Tags: SLE-MAXAI-FIRE SLE-MAXVI-FIRE StarLink

CSFM Listing: 7300-0992:0503

Date Added: 7/11/24

Models:  SLE-MAXVI-CFBPS, SLE-MAXVI-CFB, SLE-MAXVI-FIRE, SLE-MAXAI-CFBPS, SLE-MAXAI-CFB, SLE-MAXAI-FIRE, *SLE-MAX2-CFBPS, *SLE-MAX2-CFB and *SLE-MAX2-FIRE Dual Path Communicators.

The communication mode requires selection of the appropriate service plan at the point of communicator activation.  Model numbers may be followed by an alpha/numeric suffix for marketing purposes.  Products are intended for commercial/residential fire applications.  All models can function as a backup to existing telephone lines, or as a primary communicator when telephone lines are absent and when connected directly to a Listed control panel's Telco or DACT or output terminals.  Intended for indoor and dry locations only.

-----------------------------------------------

Click here for StarLink Radio Programming Video Tech Tips

 

Posted in [CSFM Listings]
Tags: SLE-MAX2-CFB SLE-MAX2-CFBPS SLE-MAX2-FIRE SLE-MAXAI-CFB SLE-MAXAI-CFBPS SLE-MAXAI-FIRE SLE-MAXVI-CFB SLE-MAXVI-CFBPS SLE-MAXVI-FIRE