Results Per Page | Showing 51-60 of 78 Results | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8

Networx Firmware - Lock PDL6600 V68j

Date Added: 10/11/17

Supports Version 2 Gateways and Expanders and the Emergency Indicator Lightbar on the inside ("protected" side) of the door.

Also includes other updated keypad programming features.

File name:  PDL6600_68j.bin

Networx PDL6600 Firmware- 68j.

Important: After updating the firmware, you MUST perform a FULL download to the lock (i.e. Users, Features, Schedules and Time/Date). Then use a valid code or card to ensure access is granted with its valid "access granted" beeps and LED lights. However, if following the valid "access granted" indication you then hear 1 long beep and 5 short beeps, the lock must then be defaulted, re-discovered and the lock profile re-downloaded. Rest assured that your Gateway always maintains your lock information. Therefore, after defaulting the lock simply re-discover the lock and DL-Windows will manage the "re-configuration process".

Note:  The firmware version letter type case ("upper case" or "lower case") displayed in the file name may differ and from the case displayed in DL-Windows.  Be aware that both letters always denote the same version.

FIRMWARE UPDATE 68j INCLUDES THE FOLLOWING NEW FEATURES:

  • Supports Lockdown Sounder on Emergency
  • Supports Lockdown Lightbar Indicator on Emergency
  • Lock responds to GLOBAL Emergency Lockdown commands
  • Lock responds to LOCAL Emergency Lockdown commands
  • Faster communication "Wake up" time when using version 2 Gateways
  • Manually unlock door using DL-Windows software (v5.5.3)

Support added for the following keypad programming options:

(AL) 8 Exit Program Mode
(AL) 67 (AL) 43 Enable Sounder on Emergency
(AL) 67 (AL) 44 Enable Inside Emergency Indicator
(AL) 67 (AL) 45 Activate Local Emergency (by keypad)
(AL) 67 (AL) 46 Activate Global Emergency (by keypad)
(AL) 67 (AL) 47 Activate Local Emergency (by keyfob; requires RR-4BKEYFOB)
(AL) 67 (AL) 48 Activate Global Emergency (by keyfob; requires RR-4BKEYFOB)

Posted in [Software / Firmware ⚙️ ]
Tags: Networx PDL6600

Networx Firmware - Lock PDL8200 V75w (beta)

Date Added: 9/3/15

(Beta version)

This firmware supports "Version 2" Gateways and Expanders!

File name:  PDL8200_75w.bin

Networx PDL8200 Firmware- 75w.

Important: After updating the firmware, you MUST perform a FULL download to the lock (i.e. Users, Features, Schedules and Time/Date). Then use a valid code or card to ensure access is granted with its valid "access granted" beeps and LED lights. However, if following the valid "access granted" indication you then hear 1 long beep and 5 short beeps, the lock must then be defaulted, re-discovered and the lock profile re-downloaded. Rest assured that your Gateway always maintains your lock information. Therefore, after defaulting the lock simply re-discover the lock and DL-Windows will manage the "re-configuration process".

Note:  The firmware version letter type case ("upper case" or "lower case") displayed in the file name may differ and from the case displayed in DL-Windows.  Be aware that both letters always denote the same version.

Posted in [Software / Firmware ⚙️ ]
Tags: PDL8200 Networx

Networx Firmware - Lock PL6100 V59c

Date Added: 4/17/12

File name:  PL6100_59c.bin

Networx PL6100 Firmware- 59c.

Important: After updating the firmware, you MUST perform a FULL download to the lock (i.e. Users, Features, Schedules and Time/Date). Then use a valid code or card to ensure access is granted with its valid "access granted" beeps and LED lights. However, if following the valid "access granted" indication you then hear 1 long beep and 5 short beeps, the lock must then be defaulted, re-discovered and the lock profile re-downloaded. Rest assured that your Gateway always maintains your lock information. Therefore, after defaulting the lock simply re-discover the lock and DL-Windows will manage the "re-configuration process".

Note:  The firmware version letter type case ("upper case" or "lower case") displayed in the file name may differ and from the case displayed in DL-Windows.  Be aware that both letters always denote the same version.

Posted in [Software / Firmware ⚙️ ]
Tags: Networx PL6100

Networx Firmware - Lock PL6100 V59d

Date Added: 6/26/17

File name:  PL6100_59d.bin

Networx PL6100 Firmware- 59d.

Important:  After updating the firmware:

A.  You MUST perform a FULL reset of the lock using the "Erase All Programming" procedure described in the PL6100 lock programming instructions.

  1. At the back of the lock, remove the lock housing screw and remove the cover.
  2. Take out battery pack and remove battery power by disconnecting the battery pack plug.
  3. With battery power disconnected, short the two white wires (Remote Input wires) together for 10 seconds to ensure discharge of all capacitors.  After 10 seconds, remove the short.
  4. Plug in the (provided) male shunt connector into the yellow wire female connector.
  5. With shunt connector connected, re-connect the battery pack.  The lock will immediately sound 3 short beeps (if these 3 beeps are not heard, then restart at step 3).
  6. The lock will then sound more slow beeps, 1 beep for every second it takes to clear the memory.
  7. Lock is ready for programming after 2 rapid beeps are heard and 2 green LED flashes are seen.

B.  Next, you MUST perform a FULL download to the lock (i.e. Users, Features, Schedules and Time/Date).  Then use a valid code or card to ensure access is granted with its valid "access granted" beeps and LED lights. 

If following the valid "access granted" indication you then hear 1 long beep and 5 short beeps, the lock must then be defaulted, re-discovered and the lock profile re-downloaded.  Rest assured that your Gateway always maintains your lock information.  Therefore, after defaulting the lock simply re-discover the lock and DL-Windows will manage the "re-configuration process".

Note:  The firmware version letter type case ("upper case" or "lower case") displayed in the file name may differ and from the case displayed in DL-Windows.  Be aware that both letters always denote the same version.

FIRMWARE UPDATE 59d INCLUDES THE FOLLOWING NEW FEATURES:

  • Supports Lockdown sounder on Emergency
  • Supports Lockdown indicator lightbar on Emergency
  • Lock responds to GLOBAL Emergency Lockdown commands
  • Lock responds to LOCAL Emergency Lockdown commands
  • Faster communication "Wake up" time when using version 2 Gateways
  • Compatible with up to 10 Wireless Remote Release buttons (RR-1BUTTON and RR-4BKEYFOB)
  • Manually unlock door using DL-Windows software (v5.5.3)

Notes:

  • Prox only "PL" models require DL-Windows software to configure most features
  • Prox only "PL" models require the RR-4BKEYFOB to initiate LOCAL Emergency commands

 

Posted in [Software / Firmware ⚙️ ]
Tags: Networx PL6100

Networx Firmware - Lock PL6200 V74a

Date Added: 3/13/13

File name:  PL6200_74a.bin

Networx PL6200 Firmware- 74a.

Important: After updating the firmware, you MUST perform a FULL download to the lock (i.e. Users, Features, Schedules and Time/Date). Then use a valid code or card to ensure access is granted with its valid "access granted" beeps and LED lights. However, if following the valid "access granted" indication you then hear 1 long beep and 5 short beeps, the lock must then be defaulted, re-discovered and the lock profile re-downloaded. Rest assured that your Gateway always maintains your lock information. Therefore, after defaulting the lock simply re-discover the lock and DL-Windows will manage the "re-configuration process".

Note:  The firmware version letter type case ("upper case" or "lower case") displayed in the file name may differ and from the case displayed in DL-Windows.  Be aware that both letters always denote the same version.

Posted in [Software / Firmware ⚙️ ]
Tags: Networx PL6200

Networx Firmware - Lock PL6500 V60.e

Date Added: 4/16/12

File name:  PL6500_60e.bin

Networx PL6500 Firmware- 60.e.

Important: After updating the firmware, you MUST perform a FULL download to the lock (i.e. Users, Features, Schedules and Time/Date). Then use a valid code or card to ensure access is granted with its valid "access granted" beeps and LED lights. However, if following the valid "access granted" indication you then hear 1 long beep and 5 short beeps, the lock must then be defaulted, re-discovered and the lock profile re-downloaded. Rest assured that your Gateway always maintains your lock information. Therefore, after defaulting the lock simply re-discover the lock and DL-Windows will manage the "re-configuration process".

Note:  The firmware version letter type case ("upper case" or "lower case") displayed in the file name may differ and from the case displayed in DL-Windows.  Be aware that both letters always denote the same version.

Posted in [Software / Firmware ⚙️ ]
Tags: Networx PL6500

Networx Firmware - Lock PL6500 V60.f

Date Added: 3/27/18

File name:  PL6500_60f.bin

Networx PL6500 Firmware- 60.f.

Important:  After updating the firmware, you MUST perform a FULL download to the lock (i.e. Users, Features, Schedules and Time/Date). Then use a valid code or card to ensure access is granted with its valid "access granted" beeps and LED lights. However, if following the valid "access granted" indication you then hear 1 long beep and 5 short beeps, the lock must then be defaulted, re-discovered and the lock profile re-downloaded. Rest assured that your Gateway always maintains your lock information. Therefore, after defaulting the lock simply re-discover the lock and DL-Windows will manage the "re-configuration process".

Note:  The firmware version letter type case ("upper case" or "lower case") displayed in the file name may differ and from the case displayed in DL-Windows.  Be aware that both letters always denote the same version.

FIRMWARE UPDATE 60f INCLUDES THE FOLLOWING NEW FEATURES:

  • Supports Lockdown Sounder on Emergency
  • Supports Lockdown indicator lightbar on Emergency
  • Lock responds to GLOBAL Emergency Lockdown commands
  • Lock responds to LOCAL Emergency Lockdown commands
  • Faster communication "Wake up" time when using version 2 Gateways
  • Manually unlock door using DL-Windows software (v5.5.3)
  • Compatible with up to 10 Wireless Remote Release Buttons (RR-1BUTTON and RR-4BKEYFOB)

Notes:
Prox only "PL" models require DL-Windows software to configure most features
Prox only "PL" models require the RR-4BKEYFOB to initiate LOCAL Emergency commands

Posted in [Software / Firmware ⚙️ ]
Tags: PL6500 Networx

Networx Firmware - Lock PL6600 V73a

Date Added: 3/8/13

File name:  PL6600_73a.bin

Networx PL6600 Firmware- 73a.

Important: After updating the firmware, you MUST perform a FULL download to the lock (i.e. Users, Features, Schedules and Time/Date). Then use a valid code or card to ensure access is granted with its valid "access granted" beeps and LED lights. However, if following the valid "access granted" indication you then hear 1 long beep and 5 short beeps, the lock must then be defaulted, re-discovered and the lock profile re-downloaded. Rest assured that your Gateway always maintains your lock information. Therefore, after defaulting the lock simply re-discover the lock and DL-Windows will manage the "re-configuration process".

Note:  The firmware version letter type case ("upper case" or "lower case") displayed in the file name may differ and from the case displayed in DL-Windows.  Be aware that both letters always denote the same version.

Posted in [Software / Firmware ⚙️ ]
Tags: Networx PL6600

Networx Firmware - NETPDK / NETDK V65a

Date Added: 2/22/13

File name:  DKNKeyPad_65a.bin

NETPDK / NETDK Firmware - 65a.

To Install: Unzip the .bin file to your C:\DL-Windows\Firmware directory. Right-click the desired NETWORXPANEL in the DL-Windows left pane and select Update Lock Firmware. Browse for the new .bin file and click OK. When finished, the confirmation screen shows the NETWORXPANEL version only (NOT the keypad version). To verify the keypad firmware: Within 10 minutes of the previously described update process, press and hold the "1" key on the keypad for 10 seconds and listen for a short beep followed by a long beep. Note: This file will update the firmware that exists within the keypad, not the NETWORXPANEL.

 

Note:  The firmware version letter type case ("upper case" or "lower case") displayed in the file name may differ and from the case displayed in DL-Windows.  Be aware that both letters always denote the same version.

Posted in [Software / Firmware ⚙️ ]
Tags: Networx NETDK NETPDK

Networx Firmware - Lock PDL8600 V79c

Date Added: 8/25/22

File name:  PDL8600_79c.bin

Networx PDL8600 Firmware- 79c.

• Firmware version 79c is a recommended critical update
• Version 79c improves the lock's data processing and data integrity

Important: After updating the firmware, you MUST perform a FULL download to the lock (i.e. Users, Features, Schedules and Time/Date). Then use a valid code or card to ensure access is granted with its valid "access granted" beeps and LED lights. However, if following the valid "access granted" indication you then hear 1 long beep and 5 short beeps, the lock must then be defaulted, re-discovered and the lock profile re-downloaded. Rest assured that your Gateway always maintains your lock information. Therefore, after defaulting the lock simply re-discover the lock and DL-Windows will manage the "re-configuration process".

Note:  The firmware version letter type case ("upper case" or "lower case") displayed in the file name may differ and from the case displayed in DL-Windows.  Be aware that both letters always denote the same version.

Posted in [Software / Firmware ⚙️ ]
Tags: PDL8600 Networx