Gemini C-Series Control Panels not integrated with the NAX-200

Date Added: 4/18/11

The Napco AccessPro NAX-200XIO Supervised Alarm/Relay Expansion Unit will not integrate with the Gemini CSeries control panels. However, you can connect a GEM-ACM1D access control module to the C-Series control panel.

Posted in [Tech Notes]
Tags:

How to Disable GEMC Outputs and Relays

Date Added: 7/28/11

How to disable (and re-enable) Gemini C-Series (GEMC) outputs and relays.

Posted in [Tech Notes]
Tags:

GEMC-Series Panel System Trouble "E14"

Date Added: 8/9/11

GEMC-Series Panel System Trouble "E14". GEMC-Series Panels with FWC-FSLC-SOM1 Supervised Output Module or FWC-FSLC-DUCT Duct Detector.

Posted in [Tech Tips]
Tags:

Wiring 4-Wire Smokes to the GEMC-EZM8

Date Added: 3/25/11

Wiring 4-Wire Smokes to the GEMC-EZM8.

Posted in [Tech Notes]
Tags:

Alarm Memory when Burg Zones go into Alarm

Date Added: 4/18/12

When an alarm is triggered on the Gemini C-Series control panels, and the panel is not fully reset, the last alarm condition description appears on the keypad together with the new alarm condition description. This Tech Note describes how to avoid this issue by fully resetting the control panel.

Posted in [Tech Notes]
Tags:

How to Set Up "Fail to Close" and "Fail to Open" upon Openings and Closings

Date Added: 11/15/11

How To Set Up "Fail To Close" And "Fail To Open" Upon Openings And Closings.

Posted in [Tech Tips]
Tags:

NAPCO GEMC Fire Alarm Specification v.01 (PDF)

Date Added: 4/4/11

NAPCO GEMC Fire Alarm Specification (PDF).

Posted in [CSI / A & E Specifications]
Tags:

New GEMC Features and Accessories Supported by Version 83A6

Date Added: 3/9/12

New GEMC Features And Accessories Supported By Version 83A6.

Posted in [Miscellaneous]
Tags:

Addendum to the GEMC-FW-SLC Installation Instructions

Date Added: 10/1/10

Addendum to the GEMC-FW-SLC Installation Instructions

Posted in [Installation Manuals]
Tags:

"Fire Alarm Verification" Not Permitted on GEMC-EZM8 Zones

Date Added: 7/28/11

Feature "Fire Alarm Verification" Not Permitted on GEMC-EZM8 Zones.

Posted in [Tech Tips]
Tags:

GEMC Control Panel System Trouble "E14"

Date Added: 3/21/11

Getting System Trouble "E14" On GEMC-Series Panels with FWC-FSLC-SOM1 Supervised Output Module or FWC-FSLC-DUCT Duct Detector.

Posted in [Tech Tips]
Tags:

Programming User Codes through the Keypad on Gemini C-Series GEMC Control Panels.

Date Added: 4/12/11

Programming User Codes through the Keypad on Gemini C-Series GEMC Control Panels.

Posted in [Tech Tips]
Tags:

Scheduling Free Access on a Gemini C-Series (GEMC) Fire Alarm System

Date Added: 6/20/12

Scheduling Free Access on a Gemini C-Series (GEMC) Fire Alarm System With GEM-ACM Access.

Posted in [Tech Notes]
Tags:

Wiring 4-Wire Smokes To The GEMC-EZM8

Date Added: 3/25/11

Wiring 4-Wire Smokes To The GEMC-EZM8. GEMC C-Series Control Panels Utilizing The GEMC-EZM8 Correction To The GEMC-EZM8 Wiring Diagram (WI1683)

Posted in [Tech Notes]
Tags:

GEMC-255MB-R (GEMC Control Panel) CAD Drawing

Date Added: 12/3/10

GEMC-255MB-R (GEMC Control Panel) CAD Drawing.

Posted in [CAD Drawings]
Tags:

GEMC-BK1 Burglary Keypad CAD Drawing

Date Added: 12/3/10

GEMC-BK1 Burglary Keypad CAD Drawing.

Posted in [CAD Drawings]
Tags:

GEMC-BSLC-1PT Single Point Expander CAD Drawing

Date Added: 12/3/10

GEMC-BSLC-1PT Single Point Expander CAD Drawing.

Posted in [CAD Drawings]
Tags:

GEMC-BSLC-RLY Single Point Relay Module CAD Drawing

Date Added: 12/3/10

GEMC-BSLC-RLY Single Point Relay Module CAD Drawing.

Posted in [CAD Drawings]
Tags:

GEMC-FK1 Fire Keypad CAD Drawing

Date Added: 12/3/10

GEMC-FK1 Fire Keypad CAD Drawing.

Posted in [CAD Drawings]
Tags:

GEMC-NACXX Supervised NAC Extender CAD Drawing

Date Added: 12/3/10

GEMC-NACXX Supervised NAC Extender CAD Drawing.

Posted in [CAD Drawings]
Tags:

GEMC-NL-MOD Network Communication Module CAD Drawing

Date Added: 12/3/10

GEMC-NL-MOD Network Communication Module CAD Drawing.

Posted in [CAD Drawings]
Tags:

GEMC-RECV Wireless RF Receiver CAD Drawing

Date Added: 12/3/10

GEMC-RECV Wireless RF Receiver CAD Drawing.

Posted in [CAD Drawings]
Tags:

GEMC-RM3008 Relay Module CAD Drawing

Date Added: 12/3/10

GEMC-RM3008 Relay Module CAD Drawing.

Posted in [CAD Drawings]
Tags:

Gemini C-Series (GEMC) Relay Programming

Date Added: 1/9/13

Gemini C-Series (GEMC) Relay Programming for models FWC-FSLC-RM2 Dual Relay Module and the FWC-FSLC-SOM1 Supervised Output Module.

Posted in [Tech Tips]
Tags:

Gemini Home / Building Automation Development Specification

Date Added: 3/14/13

Gemini Home / Building Automation Development Specification. This updated automation protocol specification includes Gemini C-Series (GEMC) building automation support.

Posted in [Miscellaneous]
Tags:

NAPCO GEMC Fire Alarm Specification v.01 (MS Word)

Date Added: 4/4/11

NAPCO GEMC Fire Alarm Specification (MS Word).

Posted in [CSI / A & E Specifications]
Tags:

Passive Infrared Sensor, GEMC-BSLC-PIR-L Installation Instructions

Date Added: 6/17/13

Passive Infrared Sensor, GEMC-BSLC-PIR-L Installation Instructions.

Posted in [Installation Manuals]
Tags:

GEMC-BSLC-DT-L "Dual Tech" Installation Instructions

Date Added: 6/10/14

Advanced Adaptive PIR / Microwave Technology Sensors
GEMC-BSLC-DT-L "Dual Tech" Installation Instructions.

Posted in [Installation Manuals]
Tags:

GEMC-Series Basic Operating Instructions

Date Added: 12/30/14

Basic Operating Instructions for the GEMC-Series Commercial Fire Alarm System.

Posted in [User Guides]
Tags:

Gemini C-Series (GEMC) Fire Trouble Relay

Date Added: 3/5/15

If a Gemini C-Series (GEMC) control panel is required to have a relay trip upon a trouble condition, the motherboard AUX Relay must be used.  This AUX Relay is the only relay in the system that will trip upon any trouble condition.

Posted in [Tech Notes]
Tags:

Gemini C-Series (GEMC) Control Panel Firmware Update Instructions

Date Added: 12/8/14

Gemini C-Series (GEMC) Control Panel Firmware Update Instructions.

Posted in [Installation Manuals]
Tags:

GEMC-SDW Schottky Diode Wire Installation Instructions

Date Added: 8/9/12

GEMC-SDW Schottky Diode Wire Installation Instructions.

Posted in [Installation Manuals]
Tags:

FWC-FSLC Signaling Line Circuit Modules

Date Added: 12/3/15

This Tech Tip describes the various Fire SLC Signaling Line Circuit modules, their functions and typical applications.

Posted in [Tech Tips]
Tags:

Trouble Codes and Conditions: Gemini and GEMC Control Panels

Date Added: 3/3/16

TROUBLE CODES AND CONDITIONS

Listed below are the trouble codes and conditions for the Gemini GEM-P816, GEM-P1632, GEM-P3200, GEM-P9600, GEM-X255 and GEMC "C-Series" control panels.

NN = Device of zone number.  Note:  "E" messages not listed here are currently undefined and reserved for future use.

E01-00 – A/C POWER FAILURE

E02-00 – SYSTEM LOW BATTERY

E03-00 – COMMUNICATIONS FAILURE OVER A PHONE LINE

E04-NN – RF TRANSMITTER SUPERVISORY FAILURE

E05-NN – RF TRANSMITTER LOW BATTERY

E06-NN – RF RECEIVER RESPONSE TROUBLE

E07-00 – DOWNLOAD ATTEMPT FAILURE

E08-00 – TELCO LINE 1 FAILURE

E09-00 – SYSTEM COLD START (NO PANEL PROGRAM)

E10-NN – BURGLARY KEYPAD RESPONSE TROUBLE

E11-NN – BURGLARY KEYPAD/ ACM TAMPER

E12-NN – BURGLARY EZM RESPONSE TROUBLE

E13-NN – BURGLARY EZM TAMPER

E14-NN – RELAY BOARD RESPONSE TROUBLE

E15-NN – RF TRANSMITTER TAMPER

E16-NN – RF RECEIVER JAMMED

E17-NN – RF RECEIVER TAMPER

E18-NN – WIRELESS KEYFOB LOW BATTERY

E19-00 – USER PROGRAM MEMORY ERROR

E20-00 – DEALER PROGRAM MEMORY ERROR

E21-00 – SYSTEM SHUT DOWN

E22-NN – SENSOR WATCH ACTIVITY FAILURE

E23-00 – BURGLARY BUS FAILURE

E24-00 – SERVICE MESSAGE

E25-00 – COMMUNICATIONS FAILURE OVER INTERNET TCP/IP 

E26-00 – SYSTEM GROUND FAULT

E27-00 – PRINTER FAILURE

E28-00 – FIRE BUS FAILURE

E29-00 – FIRE FBS BOARD TROUBLE

E30-NN – FIRE EZM AUX POWER FAILURE

E31-NN – FIRE EZM RESPONSE TROUBLE

E32-NN – FIRE KEYPAD RESPONSE TROUBLE

E33-NN – FIRE EZM TAMPER

E34-NN – FIRE KEYPAD TAMPER

E35-NN – SUPERVISORY RELAY TROUBLE

E36-NN – FIRE EZM GROUND FAULT

E37-NN – FIRE EZM A/C FAILURE

E38-NN – FIRE EZM LOW BATTERY

E39-00 – RF RECEIVER CAPACITY ERROR

E40-NN – RF DUAL TEC SELF TEST FAILURE

E41-00 – SYSTEM FIRE TROUBLE

E42-NN- CO ZONE TROUBLE

E51-00 – ALARM SUPERVISORY FAILURE

E54-00 – LOW BATTERY/AC FAIL FOR ACM #1

E55-00 – LOW BATTERY/AC FAIL FOR ACM #2

E56-00 – LOW BATTERY/AC FAIL FOR ACM #3

E57-00 – LOW BATTERY/AC FAIL FOR ACM #4

E58-00 – TELEMETRY TROUBLE

E59-00 – TELEMETRY FAILURE BETWEEN NL-MOD & PANEL

E66-00 – CLEAN ME SMOKE DETECTOR DIRTY

E99-00 – KEYPAD PANIC WIRE TROUBLE

Posted in [Miscellaneous]
Tags:

How to generate an AHJ (Authority Having Jurisdiction) Report for FWC-FSLC detectors

Date Added: 3/10/16

How to generate an AHJ (Authority Having Jurisdiction) Report for FWC-FSLC detectors.

Models:  Gemini C-Series (GEMC) / Firewolf

Posted in [Tech Tips]
Tags:

How to program the Test Timer feature (GEMC Control Panels)

Date Added: 3/17/16

How to program the Test Timer feature (GEMC Control Panels).

Posted in [Tech Tips]
Tags:

Enable Cadence for Older Fire Horns

Date Added: 6/24/16

How to enable cadence for older fire horns.

When retrofitting older GEMC / Firewolf control panels, installers may find older horns and/or 4-wire horn strobes installed. Unlike the newer smart devices, these older NAC devices may not include a pre-programmed Temporal 3 cadence. This Tech Tip describes how these older NAC devices can be wired to the control panel in order to have the control panel generate the Temporal 3 cadence.

Posted in [Tech Tips]
Tags:

Coded Alarm by Zone

Date Added: 7/12/16

This Tech Tip details the basic standard programming, configuration and installation requirements of a coded fire alarm system.

Posted in [Tech Tips]
Tags:

Programming NAC Circuits for Resettable and Non-Resettable Power

Date Added: 9/6/16

Programming NAC Circuits for Resettable and Non-Resettable Power.

Posted in [Tech Tips]
Tags:

New York City Certificate of Approval (Gemini C-Series (GEMC) Control Panels)

Date Added: 12/14/10

New York City (NYC) Certificate of Approval (GEMC).

Gemini C-Series (GEMC) Control Panels:  GEMC-32, GEMC-96, GEMC-128, GEMC-255.

 

Posted in [NYC Certificates of Approval]
Tags:

Using a GEMC Burglary Control Panel with the "My Home StarLink" Remote Arm/Disarm Mobile App

Date Added: 7/9/15

Using a GEMC Burglary Control Panel with the "My Home StarLink" Remote Arm/Disarm Mobile App.

Posted in [Tech Tips]
Tags:

How to program the different Fire Zone types in the Gemini C-Series (GEMC) control panels

Date Added: 2/23/18

How to program the different Fire Zone types in the Gemini C-Series (GEMC) control panels. 

Posted in [Video Tech Tips]
Tags:

GEMC Tripping A Monitor Zone With Auto Reset

Date Added: 4/18/18

Tripping a Monitor Zone with Auto Reset with GEMC Control Panels.

Posted in [Tech Tips]
Tags:

Programming and wiring for a Supervised NAC Extender (and Syncing)

Date Added: 4/20/18

Programming and wiring for a Supervised NAC Extender (and Syncing).

Posted in [Tech Tips]
Tags:

GEMC Programming NACs for Smart Devices

Date Added: 4/20/18

All Gemini C-Series (GEMC) and Firewolf control panels have the ability to sync System Sensor and/or
Wheelock strobes or horn/strobes.  This Tech Tip describes how to program your Fire zones for the required on-board panel NACs.

Posted in [Tech Tips]
Tags:

GEMC / FireLink Control Panel Set Up as Slave Fire Alarm DACT

Date Added: 4/17/19

This example explains how to use the FireLink FACP or Gemini C-Series (GEMC) control panels as a slave Digital Alarm Communicator Transmitter (DACT) connected to a 3rd party fire alarm system. This can be done using a GEMC-32 conventional kit as a standalone fire alarm communicator, using a FireLink FACP, or by adding a GEMC-FK1 Fire keypad, a Fire input module and a second commutation path to a GEMC Burg-only application. Note: The Gemini GEMC control panel must be running firmware V84A or later.

Posted in [Tech Tips]
Tags:

UL Fire Certification Links

Date Added: 3/25/11

UL Fire Certification Links For GEMC-Series Panels.

Posted in [UL Listings]
Tags:

Required Equipment for Continental Integration with NAPCO

Date Added: 5/21/20

To integrate NAPCO and Continental Access control panels, this Tech Tip describes the requirements.

Posted in [Tech Tips]
Tags:

Using the DSC Communicator with GEMC Platform

Date Added: 8/18/11

Using the DSC Communicator with GEMC Platform. Performing a firmware upgrade of GEMC control panel: Download firmware to micro 2 version 000.005.138.

Posted in [Tech Notes]
Tags:

UL Listing - Control Panels, SIA False Alarm Reduction

Date Added: 7/13/17

AMTB.BP2376 - Control Panels, SIA False Alarm Reduction

Burglar alarm subassemblies, driver module Model(s) GEMC-BM
Burglar alarm subassemblies, driver module/power supply Model(s) GEMC-BM/PS
Control unit accessories, low profile window / door transmitter Model(s) GEMC-WL-WDXXX+
Control unit accessories, relay module Model(s) GEMC-BSLC-RLYXXX+
Control unit accessories, zone expander module Model(s) GEMC-BSLC-1PTXXX+, GEMC-BSLC-4PTXXX+
Control unit subassemblies Model(s) GEMC-BSLC (BURG SLC Module)
+ - Where XXX is any number or letter for marketing purposes.
Last Updated on 2017-07-13

Posted in [UL Listings]
Tags:

How to Program your FireLink or GEMC Control Panel for Supervisory Alarm Auto Reset

Date Added: 5/26/21

If a supervisory zone goes into trouble, the supervisory icon and keypad sounder will automatically reset when the trouble condition clears.

 

Posted in [Video Tech Tips]
Tags:

GEMC-GFKIT Ground Fault Troubleshooting Kit Installation Instructions

Date Added: 7/27/21

GEMC-GFKIT Ground Fault Troubleshooting Kit Installation Instructions.

Also see GEMC Control Panel Ground Fault Troubleshooting Instructions.  

Posted in [Miscellaneous]
Tags:

System Sensor Cosmod2 and Cosmod4: GEMC Control Panels

Date Added: 3/3/16

The System Sensor COSMOD2 (2-wire) and COSMOD4 (4-wire) are interface modules that can integrate compatible smoke and CO detectors (and their required cadences) with the NAPCO Gemini C-Series (GEMC) control panels. When a COSMOD module is wired to a Napco control panel, control panel zones must be programmed:

FireCarbon Monoxide and Maintenance, as detailed in this Tech Note.

Posted in [Tech Notes]
Tags:

GEMC and FireLink Control Panel Set Up for Elevator Recall Using SLC Detectors and Relays

Date Added: 2/5/15

GEMC and FireLink control panel set up for elevator recall using SLC detectors and relays.

Posted in [Tech Tips]
Tags:

GEMC and FireLink Control Panel Set Up for Elevator Recall Using the GEMC-F8ZCPIM Module and the RM3008 Relay

Date Added: 1/15/15

GEMC / FireLink control panel set up for elevator recall using the GEMC-F8ZCPIM module and the RM3008 relay.

Posted in [Tech Tips]
Tags:

Programming FWC-FSLC-EZM2 Dual Input Monitor Module in Quickloader

Date Added: 10/16/14

Programming FWC-FSLC-EZM2 Dual Input Monitor Module in PCD-Windows Quickloader.

Posted in [Tech Tips]
Tags:

Programming a 6-hour Test Timer using Quickloader

Date Added: 7/21/22

Ever since the NFPA 72 (2013) was instituted, a 6-hour Test Timer may be required to be programmed in your Gemini C-Series (GEMC), Firewolf or FireLink control panel.  See this Tech Tip for programming instructions.

Posted in [Tech Tips]
Tags:

Gemini C-Series (GEMC) Standby Calculation Worksheet

Date Added: 12/10/18

Gemini C-Series (GEMC) Standby Calculation Worksheet (MS Excel file).

Posted in [Battery Standby Calc. Worksheets]
Tags:

UL 864: (10th Edition) UL Control Units, System

Date Added: 11/22/21

UL 864 (10th Edition) UL Control Units, System.  UL File UOJZ.S3594

Last Updated on 2021-11-22

Posted in [UL Listings]
Tags:

Using PCD-Windows Quickloader to Update GEMC/FireLink Control Panel Firmware

Date Added: 3/2/23

How to update GEMC/FireLink control panel firmware using PCD-Windows Quickloader software:

Posted in [Video Tech Tips]
Tags:

Using the Fire Aux Relay for 24V Resettable Fire Power

Date Added: 3/22/23

Using the Fire Aux Relay for 24V Resettable Fire Power with the FireLink and Gemini C-Series (GEMC) control panels.

Posted in [Tech Tips]
Tags:

Firmware for the Gemini C-Series (GEMC) Control Panels

Date Added: 4/19/23

Firmware for the Gemini C-Series (GEMC) Control Panels, version 90.72.

Posted in [Software / Firmware]
Tags:

GEMC RM2 Relay Module and SOM Output Module Programming

Date Added: 6/14/13

GEMC RM2 Relay Module and SOM Output Module Programming.

Posted in [Tech Notes]
Tags:

NAPCO FireLink Standby Current Calculation Worksheet

Date Added: 2/21/23

NAPCO FireLink Standby Current Calculation Worksheet (MS Excel file).

Posted in [Battery Standby Calc. Worksheets]
Tags:

CSFM Listing: 7165-0992:0501

Date Added: 8/18/23

Models FL-32FACP, FL-96FACP, FL-128FACP, FL-255FACP; FL-32FACP-A, FL-96FACP-A, FL-128FACP-A, FL-255FACP-A, *FL-32FACP-LTEAI, *FL-96FACP-LTEAI, *FL-128FACP-LTAI, *FL-255FACP-LTAI, *FL-32FACP-LTEVI, *FL-96FACP-LTEVI, *FL-128FACP-LTVI, *FL-255FACP-LTVI, *FL-32FACP-LTEAS, *FL-96FACP-LTEAS, *FL-128FACP-LTAS, *FL-255FACP-LTAS *FL-32FACP-LTEVS, *FL-96FACP-LTEVS, *FL-
128FACP-LTVS and *FL-255FACP-LTVS fire alarm control units. Automatic, manual, waterflow and sprinkler supervisory service, local, remote station (PPU) and central station (PPU). Models with Suffix “A” indicate integral GSM radio and models without suffix “A” integral CDMA radio. All Models may be followed by three alphanumeric characters. *Models with suffix LTEVS/LTEAS/LTVS/LTSA are Sole Path radios. *Models with suffix LTEVI/LTEAI/LTVI/LTAI are Dual Path radios.

System components:
GEMC-HSKIT1416, HSKIT1425; Enclosure
GEMC-32MB, GEMC-96MB, GEMC-128MB, GEMC-255MB; Main Boards
GEMC-PS24V4A, GEMC-PS24V7A; Power Supply
GEMC--FW-SLC; Fire Signaling Line Circuit Modules
GEMC-F8ZCPIM; Zone Expander Modules
GEMC-24VR; 24V Output Module
GEMC-FK1; Keypad
9SLECDMAIPSLD or 9SLEGSMDPPSLD; SLE Duel Path Communicators

Refer to listee's data sheet for detailed product description and operational considerations.

Posted in [CSFM Listings]
Tags:

GEMC-HSKIT1416 Smaller GEMC-FireLink Control Panel Enclosure Dimensions

Date Added: 9/29/23

GEMC-HSKIT1416 Smaller GEMC / FireLink Control Panel Enclosure Dimensions.  WinZip file contains equivalent .PDF and .DWG files.  

Posted in [Data Sheets - AHJ Submittal]
Tags:

GEMC-HSKIT1425 Larger GEMC / FireLink Control Panel Enclosure Dimensions

Date Added: 9/29/23

GEMC-HSKIT1425 Larger GEMC / FireLink Control Panel Enclosure Dimensions.  WinZip file contains equivalent .PDF and .DWG files.

Posted in [Data Sheets - AHJ Submittal]
Tags:

Preventing Ground Faults when Installing GEMC Power Supply PC Boards

Date Added: 12/28/23

Tech Tip:  Preventing Ground Faults when Installing GEMC Power Supply PC Boards.

Posted in [Tech Tips]
Tags:

GEMC-EZM8 Zone Expansion Module CAD Drawing

Date Added: 1/29/24

GEMC-EZM8 Zone Expansion Module CAD Drawing.

Posted in [CAD Drawings]
Tags: